WEKO3
アイテム
Effects of Neo Automatic Code on the Accuracy of Chest Compression Depths in Cardiac Arrest Patients
https://hiroshima.repo.nii.ac.jp/records/2013781
https://hiroshima.repo.nii.ac.jp/records/2013781be2150c7-977e-4288-a6ce-597160a3b134
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
| Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2023-03-18 | |||||||||||
| タイトル | ||||||||||||
| タイトル | Effects of Neo Automatic Code on the Accuracy of Chest Compression Depths in Cardiac Arrest Patients | |||||||||||
| 言語 | en | |||||||||||
| 作成者 |
Darmawan, Rendi Editya
× Darmawan, Rendi Editya
× Sujianto, Untung
× Rochana, Nana
|
|||||||||||
| アクセス権 | ||||||||||||
| アクセス権 | open access | |||||||||||
| アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
| 権利情報 | ||||||||||||
| 権利情報 | Copyright (c) 2018 Hiroshima University Medical Press | |||||||||||
| 主題 | ||||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | cardiac arrest | |||||||||||
| 主題 | ||||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | chest compression | |||||||||||
| 主題 | ||||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | compression depth accuracy | |||||||||||
| 主題 | ||||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | neo automatic | |||||||||||
| 主題 | ||||||||||||
| 主題Scheme | NDC | |||||||||||
| 主題 | 490 | |||||||||||
| 内容記述 | ||||||||||||
| 内容記述 | Objective: to analyze the effects of manual chest compression using neo automatic code on the accuracy of compression depths. Methods: This study used a quantitative, post test quasi-experimental design with a control group. The samples were 74 cardiac arrest patients in two hospitals in Surakarta and Klaten, who were selected using purposive sampling technique. The data were analyzed by the Mann-Whitney test. Results: the mean of accuracy of compression depth in the control group was 68.10 ± 17.60%, and in the treatment group was 83 ± 6.04%. The result of statistical analysis showed that there were differences in the accuracy of compression depth in the intervention and control group with p-value of 0.000. Conclusion: there were effects of manual chest compression using neo automatic code on the accuracy of compression depths. Neo automatic code could improve the accuracy of chest compression depths. | |||||||||||
| 言語 | en | |||||||||||
| 出版者 | ||||||||||||
| 出版者 | Hiroshima University Medical Press | |||||||||||
| 言語 | ||||||||||||
| 言語 | eng | |||||||||||
| 資源タイプ | ||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
| 資源タイプ | departmental bulletin paper | |||||||||||
| 出版タイプ | ||||||||||||
| 出版タイプ | VoR | |||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||
| 収録物識別子 | ||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||
| 収録物識別子 | 0018-2052 | |||||||||||
| 収録物識別子 | ||||||||||||
| 収録物識別子タイプ | NCID | |||||||||||
| 収録物識別子 | AA00664312 | |||||||||||
| 開始ページ | ||||||||||||
| 開始ページ | 161 | |||||||||||
| 書誌情報 |
Hiroshima Journal of Medical Sciences Hiroshima Journal of Medical Sciences 巻 67, p. 161-165, 発行日 2018-05 |
|||||||||||