{"created":"2025-02-23T06:43:28.088559+00:00","id":2013781,"links":{},"metadata":{"_buckets":{"deposit":"f20bad38-22c2-45b3-8396-d6e95c18547e"},"_deposit":{"created_by":41,"id":"2013781","owners":[41],"pid":{"revision_id":0,"type":"depid","value":"2013781"},"status":"published"},"_oai":{"id":"oai:hiroshima.repo.nii.ac.jp:02013781","sets":["1727147343679:1730442224523:1730442235519"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"Effects of Neo Automatic Code on the Accuracy of Chest Compression Depths in Cardiac Arrest Patients","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Darmawan, Rendi Editya","creatorNameLang":"en"}],"familyNames":[{"familyName":"Darmawan","familyNameLang":"en"}],"givenNames":[{"givenName":"Rendi Editya","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Sujianto, Untung","creatorNameLang":"en"}],"familyNames":[{"familyName":"Sujianto","familyNameLang":"en"}],"givenNames":[{"givenName":"Untung","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Rochana, Nana","creatorNameLang":"en"}],"familyNames":[{"familyName":"Rochana","familyNameLang":"en"}],"givenNames":[{"givenName":"Nana","givenNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2018 Hiroshima University Medical Press"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_subject":"cardiac arrest","subitem_subject_scheme":"Other"},{"subitem_subject":"chest compression","subitem_subject_scheme":"Other"},{"subitem_subject":"compression depth accuracy","subitem_subject_scheme":"Other"},{"subitem_subject":"neo automatic","subitem_subject_scheme":"Other"},{"subitem_subject":"490","subitem_subject_scheme":"NDC"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Objective: to analyze the effects of manual chest compression using neo automatic code on the accuracy of compression depths. Methods: This study used a quantitative, post test quasi-experimental design with a control group. The samples were 74 cardiac arrest patients in two hospitals in Surakarta and Klaten, who were selected using purposive sampling technique. The data were analyzed by the Mann-Whitney test. Results: the mean of accuracy of compression depth in the control group was 68.10 ± 17.60%, and in the treatment group was 83 ± 6.04%. The result of statistical analysis showed that there were differences in the accuracy of compression depth in the intervention and control group with p-value of 0.000. Conclusion: there were effects of manual chest compression using neo automatic code on the accuracy of compression depths. Neo automatic code could improve the accuracy of chest compression depths.","subitem_description_language":"en"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"Hiroshima University Medical Press"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0018-2052","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA00664312","subitem_source_identifier_type":"NCID"}]},"item_1617187024783":{"attribute_name":"開始ページ","attribute_value_mlt":[{"subitem_start_page":"161"}]},"item_1617187056579":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"165","bibliographicPageStart":"161","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"Hiroshima Journal of Medical Sciences"},{"bibliographic_title":"Hiroshima Journal of Medical Sciences"}]}]},"item_1617258105262":{"attribute_name":"item_1617258105262","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-03-18"}],"displaytype":"simple","filename":"HiroshimaJMedSci_67s_161.pdf","filesize":[{"value":"212.2 KB"}],"mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hiroshima.repo.nii.ac.jp/record/2013781/files/HiroshimaJMedSci_67s_161.pdf"},"version_id":"57ffa0ea-4684-4f9f-9c82-d15dcf3236c3"}]},"item_1732771732025":{"attribute_name":"旧ID","attribute_value":"45860"},"item_title":"Effects of Neo Automatic Code on the Accuracy of Chest Compression Depths in Cardiac Arrest Patients","item_type_id":"40003","owner":"41","path":["1730442235519"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-03-18"},"publish_date":"2023-03-18","publish_status":"0","recid":"2013781","relation_version_is_last":true,"title":["Effects of Neo Automatic Code on the Accuracy of Chest Compression Depths in Cardiac Arrest Patients"],"weko_creator_id":"41","weko_shared_id":-1},"updated":"2025-06-02T03:32:27.300211+00:00"}