WEKO3
アイテム
ネオバーによる気管内チューブ固定法に関する検討
https://hiroshima.repo.nii.ac.jp/records/2025629
https://hiroshima.repo.nii.ac.jp/records/20256298fe9c5ae-1422-4fc1-9966-4ee419d11e6a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-18 | |||||||||
タイトル | ||||||||||
タイトル | ネオバーによる気管内チューブ固定法に関する検討 | |||||||||
言語 | ja | |||||||||
タイトル | ||||||||||
タイトル | Consideration of endotracheal tube fixing by NeoBar | |||||||||
言語 | en | |||||||||
作成者 |
嶋野, 雅子
× 嶋野, 雅子
|
|||||||||
アクセス権 | ||||||||||
アクセス権 | open access | |||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | ネオバー | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | 気管内チューブ | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | NeoBar | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | endotracheal tube | |||||||||
主題 | ||||||||||
主題Scheme | NDC | |||||||||
主題 | 490 | |||||||||
内容記述 | ||||||||||
内容記述 | 当院の気管内挿管の特徴は,初回気管内挿管は絆創膏による固定法を採用している.再固定の時には,ネオバーを気管内チューブ固定に使用するようになった.これまでの実施した結果をもとに,気管内チューブ固定をネオバーに使用することの利点と欠点について考察した.ネオバーを使用することの利点は,(1)固定位置が口角から離れており口腔内分泌物による影響がない(2)気管内チューブの位置確認や位置変更が簡便である(3)皮膚への影響が小さい(4)新生児の大きさに合せてサイズを選択できるなどのおもな4点が挙げられる.ネオバーを使用することの欠点は,(1)緊急時や急性期の新生児には適用できない(2)眼科検査や手術の妨げになりうることが挙げられる.計画外抜管を予防するためには,さらにネオバーの使い方を工夫することが必要である. | |||||||||
言語 | ja | |||||||||
内容記述 | ||||||||||
内容記述 | In this hospital, the way of fixing an endotracheal tube at first was by using an adhesive plaster. We began to use NeoBar during the second time of fixing tubes. As a result of our practice, we considered the merits and demerits of using NeoBar.There were 4 main merits of using NeoBar: 1) The fixed place was not close to side of mouth, so that saliva didn't affect it, 2) it was easy to check and change place of a tube in the trachea, 3) it caused small damage to the skin, and 4) we were able to change size for each newborn baby.However, there were 2 demerits: 1) It was not suitable for emergency, or acute newborn babies, and 2) it was an obstacle to an ophthalmology checkup or an operation.It is suggested that we need to contrive a method of using NeoBar so that unplanned coming off a tube can be prevented. | |||||||||
言語 | en | |||||||||
出版者 | ||||||||||
出版者 | 日本新生児看護学会 | |||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
出版タイプ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 1343-9111 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | NCID | |||||||||
収録物識別子 | AA11269499 | |||||||||
開始ページ | ||||||||||
開始ページ | 39 | |||||||||
書誌情報 |
日本新生児看護学会誌 Journal of Japan Academy of Neonatal Nursing 巻 11, 号 2, p. 39-41, 発行日 2005-06 |
|||||||||
旧ID | 176 |