ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. IPSHU Research Report Series
  3. 28号

Reported Occurrence of Severe Epilation vs. Location among the Life Span Study Cohort of Atomic Bomb Survivors

https://doi.org/10.15027/33624
https://doi.org/10.15027/33624
c732333a-63e8-46d9-87fb-dca6211190be
名前 / ファイル ライセンス アクション
ipshu_en_28_45.pdf ipshu_en_28_45.pdf (11.4 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Reported Occurrence of Severe Epilation vs. Location among the Life Span Study Cohort of Atomic Bomb Survivors
言語 en
作成者 Cullings, Harry

× Cullings, Harry

en Cullings, Harry

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2012 Institute for Peace Science, Hiroshima University
主題
主題Scheme NDC
主題 319
内容記述
内容記述 There has long been a concern that clinical symptoms of acute radiation injury, reported by survivors in the questionnaires used by the Atomic Bomb Casualty Commission (ABCC) in the 1950s to gather information for creation of the Life Span Study cohort, were reported at low but non-zero proportions in relatively distal survivors. Because the data were self-reported, there were various potential sources of error that could have resulted in false-positive data. In the most definitive RERF studies, severe epilation (of scalp hair) has been considered to be the most specific and reliable of the reported symptoms potentially related to acute radiation injury. The data on severe epilation: 1,288 cases in Hiroshima and 384 in Nagasaki, have been subjected to a new, exploratory spatial analysis, to see if there are any patterns that might plausibly be associated with exposure to residual radiation. A method used by RERF investigators in 1983 to check for circular asymmetry about the hypocenters, by comparing compass octants in various directions, was repeated with DS02 dose estimates, and a parametric model for dose response including octant indicators was also fitted. In addition, the cities were divided into 200-yard-square geospatial cells and spatial plots were made of the proportions in the cells to allow visualization of any patterns that might exist. A result was that all of the cells with more than a few cases of severe epilation were within about 1.6 km of the hypocenters, consistent with the epilation expected for the corresponding DS02 doses. Among the more distal cells were a number of cells with one or two cases per cell, which are increasingly sparse at longer distances and otherwise appear to be randomly distributed in location — no pattern potentially associated with fallout is obvious on visual inspection. In the future these data may be further analyzed with spatial methods appropriate for binomial random variables with possible spatial autocorrelation, which must also correct for expected proportions due to DS02 dose.
言語 en
出版者
出版者 広島大学平和科学研究センター
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.15027/33624
ID登録タイプ JaLC
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA10456537
開始ページ
開始ページ 45
書誌情報 IPSHU English Research Report Series
IPSHU English Research Report Series

号 28, p. 45-56, 発行日 2012-03
旧ID 33624
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-27 04:20:22.301869
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3