Prevention of COVID-19 infection in the delivery room by assessing smoke test visualization of exhaled air

https://hiroshima.repo.nii.ac.jp/records/2013828
https://hiroshima.repo.nii.ac.jp/records/2013828
2dac9cb5-1766-4e48-88a3-0e2841a07456
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_73_15.pdf HiroshimaJMedSci_73_15.pdf (7.8 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2024-08-07
タイトル
タイトル Prevention of COVID-19 infection in the delivery room by assessing smoke test visualization of exhaled air
言語 en
作成者 MUKAI, Yurika

× MUKAI, Yurika

en MUKAI, Yurika

Search repository
SADAKANE, Takako

× SADAKANE, Takako

en SADAKANE, Takako

Search repository
TOYOTA, Yukari

× TOYOTA, Yukari

en TOYOTA, Yukari

Search repository
KATO, Takahiro

× KATO, Takahiro

en KATO, Takahiro

Search repository
KOH, Iemasa

× KOH, Iemasa

en KOH, Iemasa

Search repository
SAEKI, Noboru

× SAEKI, Noboru

en SAEKI, Noboru

Search repository
KUDO, Yoshiki

× KUDO, Yoshiki

en KUDO, Yoshiki

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 en
権利情報 Copyright (c) 2024 Hiroshima University Medical Press
主題
言語 en
主題Scheme Other
主題 COVID-19
主題
言語 en
主題Scheme Other
主題 Delivery room
主題
言語 en
主題Scheme Other
主題 Respiratory aerosols and droplets
主題
言語 en
主題Scheme Other
主題 Smoke test
内容記述
内容記述 The principal route of the coronavirus disease 2019 (COVID-19) infection is through the inhalation of respiratory droplets and aerosols. To date, there are no reports on the control of aerosol-mediated infections during vaginal delivery. This study aimed to visualize the airflow in a delivery room and use this information to develop infection control measures. A tracheal intubation practice manikin was used for the experiment. Smoke was generated using fog liquid and a fog machine. Smoke was collected in a plastic bag connected to the lower pharynx of the manikin via a conduit. Exhaled airflow was visualized by irradiating exhaled smoke with a laser beam. We visualized the aerosol flow from the mouth and nose of the manikin by compressing a plastic bag filled with smoke. We performed a smoke test to check the expiratory flow and accordingly modified the delivery room in two ways: the head side of the delivery table was surrounded with a plastic sheet, and the exhaust pipe was passed through the vinyl sheet to the exhaust port. After these modifications, we managed 18 vaginal deliveries in parturient women with COVID-19, with no related infections among the babies or staff. With emerging infectious diseases, such as COVID-19, the route of infection may be unclear and determining appropriate infection control measures can be difficult. By considering the characteristics of the virus and implementing appropriate infection control measures, we can safely manage high-risk vaginal deliveries.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
開始ページ
開始ページ 15
書誌情報 en : Hiroshima Journal of Medical Sciences

巻 73, 号 1-2, p. 15-21, ページ数 7, 発行日 2024-06
旧ID 55343
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:44:56.932115
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3