ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 58巻4号

Arterial Mechanical Impedance is a Sensitive Stress Response Monitor During General Anesthesia

https://hiroshima.repo.nii.ac.jp/records/2013620
https://hiroshima.repo.nii.ac.jp/records/2013620
14c063a7-1fa9-407b-a62b-176fca83fe4e
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_58_75.pdf HiroshimaJMedSci_58_75.pdf (1.9 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Arterial Mechanical Impedance is a Sensitive Stress Response Monitor During General Anesthesia
言語 en
作成者 Nakamura, Ryuji

× Nakamura, Ryuji

en Nakamura, Ryuji

Search repository
Saeki, Noboru

× Saeki, Noboru

en Saeki, Noboru

Search repository
Kutluk, Abdugheni

× Kutluk, Abdugheni

en Kutluk, Abdugheni

Search repository
Shiba, Kenji

× Shiba, Kenji

en Shiba, Kenji

Search repository
Tsuji, Toshio

× Tsuji, Toshio

en Tsuji, Toshio

Search repository
Hamada, Hiroshi

× Hamada, Hiroshi

en Hamada, Hiroshi

Search repository
Kawamoto, Masashi

× Kawamoto, Masashi

en Kawamoto, Masashi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 (c) Hiroshima University Medical Press.
主題
主題Scheme Other
主題 Plethysmography
主題
主題Scheme Other
主題 Autonomic response
主題
主題Scheme Other
主題 Depth of anesthesia
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethysmographic amplitude to estimate the magnitude of stress response in patients undergoing general anesthesia by measuring direct arterial pressure. After sedating each patient with propofol, photoplethysmographic amplitude and mechanical impedance were measured as baseline control values, then 3 min after fentanyl administration (2 μg kg-1 ), the parameters were measured again as post-fentanyl values. Thereafter, a direct laryngoscopy procedure was performed and post-laryngoscopy values for the parameters were determined. The magnitudes of response to each event were compared by using the ratio of the measurements from the preceding event. Then, comparisons of the magnitudes were performed after coordinating each response in the same direction. Our results showed that both stiffness and viscosity of mechanical impedance had greater variations than photoplethysmographic amplitude. In conclusion, we propose stiffness and viscosity derived from arterial mechanical impedance as sensitive parameters to monitor stress responses during general anesthesia.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 75
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 58, 号 4, p. 75-82, 発行日 2009-12
旧ID 34970
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:38:39.671947
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3