ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 55巻2号

Transrectal Ultrasound-guided 10-core Biopsy of the Prostate for Japanese Patients

https://hiroshima.repo.nii.ac.jp/records/2013579
https://hiroshima.repo.nii.ac.jp/records/2013579
4e73d154-3e79-4cae-a068-ff9de0dacee9
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_55_65.pdf HiroshimaJMedSci_55_65.pdf (62.4 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Transrectal Ultrasound-guided 10-core Biopsy of the Prostate for Japanese Patients
言語 en
作成者 Matsubara, Akio

× Matsubara, Akio

en Matsubara, Akio

Search repository
Mutaguchi, Kazuaki

× Mutaguchi, Kazuaki

en Mutaguchi, Kazuaki

Search repository
Yasumoto, Hiroaki

× Yasumoto, Hiroaki

en Yasumoto, Hiroaki

Search repository
Takeshima, Yukio

× Takeshima, Yukio

en Takeshima, Yukio

Search repository
Teishima, Jun

× Teishima, Jun

en Teishima, Jun

Search repository
Seki, Mitsuhiro

× Seki, Mitsuhiro

en Seki, Mitsuhiro

Search repository
Hasegawa, Yasuhiro

× Hasegawa, Yasuhiro

en Hasegawa, Yasuhiro

Search repository
Usui, Tsuguru

× Usui, Tsuguru

en Usui, Tsuguru

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 (c) Hiroshima University Medical Press.
主題
主題Scheme Other
主題 Prostate cancer
主題
主題Scheme Other
主題 Biopsy
主題
主題Scheme Other
主題 Japanese
主題
主題Scheme Other
主題 PSA
主題
主題Scheme NDC
主題 490
内容記述
内容記述 To determine the utility of transrectal ultrasound (TRUS)-guided 10-core prostate biopsy (sextant plus 4 far lateral cores) for Japanese patients, we compared it with the standard sextant for detection of prostate cancer. The study patients were 564 consecutive Japanese men (median age 71 years) who underwent 10-core biopsy because of PSA values of ≥ 2.0 ng/ml at Hiroshima University Hospital between March 2000 and December 2004. The overall cancer detection rate for the 10-core biopsy was 42.6% (240/564), which was significantly higher than the 36.3% (205/564) for the standard sextant biopsy (P=0.0330), with a 14.6% (35/240) improvement. The 10-core biopsy also detected a significant number of additional cancers in the subgroups of patients with PSA values of 2~10 ng/ml (P=0.0275), a prostate volume of > 20 cc (P=0.0440), or normal findings of digital rectal examination (P=0.0304). The 10-core biopsy scheme detected 9.6% and 2.1~8.3% more cancers than the lateral sextant (apex, lateral mid portion, and lateral base) and the probable different combinations of 8-core biopsy designs, respectively. Compared to the standard sextant biopsy, the 10-core biopsy did not detect an increased proportion of clinically insignificant cancers. There was no severe morbidity, and only 2 patients (0.4%) were briefly hospitalized due to high fever. These results show that the TRUSguided 10-core biopsy yields a better prostate cancer detection rate than the 6-core or 8-core protocol without severe complications. Therefore, it seems to be practicable for Japanese patients.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 65
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 55, 号 2, p. 65-70, 発行日 2006-06
旧ID 34929
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:37:25.572137
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3