ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 55巻2号

Evoked Spinal Cord Potentials Monitored at Thoracoabdominal Region after Trans-intercostal Stimulation

https://hiroshima.repo.nii.ac.jp/records/2013577
https://hiroshima.repo.nii.ac.jp/records/2013577
0384686d-ce12-4fb2-b2e7-f3e85902d7f2
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_55_53.pdf HiroshimaJMedSci_55_53.pdf (3.2 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Evoked Spinal Cord Potentials Monitored at Thoracoabdominal Region after Trans-intercostal Stimulation
言語 en
作成者 Kumagai, Hajime

× Kumagai, Hajime

en Kumagai, Hajime

Search repository
Orihashi, Kazumasa

× Orihashi, Kazumasa

en Orihashi, Kazumasa

Search repository
Isaka, Mitsuhiro

× Isaka, Mitsuhiro

en Isaka, Mitsuhiro

Search repository
Hamaishi, Makoto

× Hamaishi, Makoto

en Hamaishi, Makoto

Search repository
Sueda, Taijiro

× Sueda, Taijiro

en Sueda, Taijiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 (c) Hiroshima University Medical Press.
主題
主題Scheme Other
主題 Intercostal nerve stimulation
主題
主題Scheme Other
主題 Evoked spinal cord potential monitoring
主題
主題Scheme Other
主題 Thoracoabdominal region
主題
主題Scheme NDC
主題 490
内容記述
内容記述 To investigate the feasibility of a novel recording method for trans-intercostal evoked spinal cord potentials (Tic-ESCPs) and the properties of the waveforms, the potentials were recorded and analyzed in an animal model. In two beagle dogs, Tic-ESCPs were recorded at the left twelfth intercostal to fourth lumbar nerves following stimulation at the left eleventh intercostal nerve, either with or without the use of a muscle relaxant. The amplitude and latency of the Tic-ESCP waves were then measured and compared with those of conventional transcranial spinal motor evoked potentials (MEPs). Tic-ESCPs could be obtained at any nerve, with or without the use of a muscle relaxant. The Tic-ESCP waveform was clear and simple, consisting of a small positive (P1) wave and a subsequent large negative (N1) wave. As the site of recording moved farther from the stimulation site, the N1 amplitudes were reduced and the P1 latency was prolonged. Under muscle relaxation, the N1 amplitudes were reduced, and the P1 latencies were shorter. As compared with MEPs, Tic-ESCPs could be evoked by a weaker stimulus, the N1 amplitude was smaller, and the P1 latency was shorter. Tic-ESCP recording was feasible either with or without the use of a muscle relaxant. The Tic-ESCPs showed simple and clear waveforms with smaller stimulations. Therefore, Tic-ESCPs may be useful for intraoperative spinal cord monitoring.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 53
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 55, 号 2, p. 53-57, 発行日 2006-06
旧ID 34927
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:37:21.955558
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3