Distance from the Skin to the Epidural Space at the First Lumbar Interspace in a Japanese Obstetric Population

https://hiroshima.repo.nii.ac.jp/records/2013532
https://hiroshima.repo.nii.ac.jp/records/2013532
3a73e69a-dd6d-40ab-9af5-2d3804196832
名前 / ファイル ライセンス アクション
KJ00000705979.pdf KJ00000705979.pdf (300.0 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2006-03-21
タイトル
タイトル Distance from the Skin to the Epidural Space at the First Lumbar Interspace in a Japanese Obstetric Population
言語 en
作成者 Shiroyama, Kazuhisa

× Shiroyama, Kazuhisa

en Shiroyama, Kazuhisa

Search repository
Izumi, Hiromichi

× Izumi, Hiromichi

en Izumi, Hiromichi

Search repository
Kubo, Takashi

× Kubo, Takashi

en Kubo, Takashi

Search repository
Nakamura, Ryuji

× Nakamura, Ryuji

en Nakamura, Ryuji

Search repository
寄与者
姓名 国立情報学研究所
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Distance
主題
主題Scheme Other
主題 Epidural space
主題
主題Scheme Other
主題 Lumbar interspace
主題
主題Scheme Other
主題 Obstetric
主題
主題Scheme NDC
主題 490
内容記述
内容記述 We prospectively examined the distance from the skin to the epidural space (SE distance) in 95 Japanese parturient women who underwent epidural anesthesia at the L1-2 interspace, and studied the correlation between various physical factors and SE distance. The same anesthesiologist inserted the epidural tubing with the patient in the right lateral decubitus position. An epidural needle was introduced into the skin vertically via the midline approach. The epidural space was located using the loss-of-resistance technique. SE distance was measured to the nearest 0.5 cm using centimeter markings on the shaft of the epidural needle. The median value of SE distance was 3.5 cm, with a range of 2.5 to 6.5 cm, and in 800f cases SE distances were 3 to 4 cm. The correlation of body weight with SE distance was the highest of the physical factors (r^2 = 0.800, p = 0.0001), and a simple regression equation was formulated to aid in predicting SE distance: 'SE distance (cm) = 0.05 × body weight (kg) + 0.36'. This formula will be a useful clinical guide for administering epidural anesthesia in Japanese parturient women. In conclusion, the SE distance in most Japanese parturient women is between 3 and 4 cm at the L1-2 interspace and this value is most closely correlated with their body weight.
言語 en
出版者
出版者 Hiroshima University Medical Press
日付
日付 2006-03-21
日付タイプ Created
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 27
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 52, 号 2, p. 27-29, 発行日 2003-06
旧ID 900
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:36:05.222271
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3