ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 50巻4号

A Formula Based on Body Length for Determining the Size of an Uncuffed Endotracheal Tube for Pediatric Cardiac Anesthesia

https://hiroshima.repo.nii.ac.jp/records/2013512
https://hiroshima.repo.nii.ac.jp/records/2013512
60f13e6f-916c-498b-b1b0-27139afdcc95
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_50_97.pdf HiroshimaJMedSci_50_97.pdf (265.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル A Formula Based on Body Length for Determining the Size of an Uncuffed Endotracheal Tube for Pediatric Cardiac Anesthesia
言語 en
作成者 Shiroyama, Kazuhisa

× Shiroyama, Kazuhisa

en Shiroyama, Kazuhisa

Search repository
Izumi, Hiromichi

× Izumi, Hiromichi

en Izumi, Hiromichi

Search repository
Kubo, Takashi

× Kubo, Takashi

en Kubo, Takashi

Search repository
Kawamoto, Masashi

× Kawamoto, Masashi

en Kawamoto, Masashi

Search repository
Yuge, Osafumi

× Yuge, Osafumi

en Yuge, Osafumi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Endotracheal tube size
主題
主題Scheme Other
主題 Formula for prediction
主題
主題Scheme Other
主題 Body length
主題
主題Scheme Other
主題 Pediatric cardiac anesthesia
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Three hundred and thirty-four pediatric patients less than 4 years old who underwent surgery for congenital heart disease were retrospectively studied to devise a practical formula for predicting the appropriate size for an uncuffed endotracheal tube for pediatric cardiac anesthesia. Furthermore, this formula was compared with that for non-cardiac anesthesia obtained from 409 patients without congenital heart disease. A simple regression equation between tube size and body length resulted in the simple predictive formula: "tube size= 0.04 x body length+ 1.6" for pediatric cardiac anesthesia. This formula had the same slope and an approximately 0.3 mm larger intercept on the Y-axis compared with that for pediatric non-cardiac anesthesia. Therefore, a one-size larger endotracheal tube is more suitable for use in pediatric cardiac anesthesia than in pediatric non-cardiac anesthesia for the same body length.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 97
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 50, 号 4, p. 97-99, 発行日 2001-12
旧ID 37693
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:35:30.760659
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3