A Case of Traumatic Pseudoaneurysm of the Ascending Aorta occurring in a Postoperative Patient who underwent Arch Replacement and Bentall's Operation

https://hiroshima.repo.nii.ac.jp/records/2013382
https://hiroshima.repo.nii.ac.jp/records/2013382
25c3d6d2-88ba-4292-8956-f16fe509211e
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_44_145.pdf HiroshimaJMedSci_44_145.pdf (386.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル A Case of Traumatic Pseudoaneurysm of the Ascending Aorta occurring in a Postoperative Patient who underwent Arch Replacement and Bentall's Operation
言語 en
作成者 Kochi, Kazuhiro

× Kochi, Kazuhiro

en Kochi, Kazuhiro

Search repository
Imai, Katsuhiko

× Imai, Katsuhiko

en Imai, Katsuhiko

Search repository
Shiraga, Koutaro

× Shiraga, Koutaro

en Shiraga, Koutaro

Search repository
Kono, Satoshi

× Kono, Satoshi

en Kono, Satoshi

Search repository
Komiya, Tatsuhiko

× Komiya, Tatsuhiko

en Komiya, Tatsuhiko

Search repository
Kanzaki, Yoshio

× Kanzaki, Yoshio

en Kanzaki, Yoshio

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Traumatic Pseudoaneurysm
主題
主題Scheme NDC
主題 490
内容記述
内容記述 A case of traumatic pseudoaneurysm of the ascending aorta occurring in a postoperative patient who underwent an arch replacement and Bentall's operation was reported. A bleeding point was clear at the graft of the ascending aorta, and a pseudoaneurysmal formation was suspected following an echocardiogram. An aortogram demonstrated the presence of an aneurysm approximately 8 cm by 4 cm in size originating 5 cm above the right coronary ostia. An emergency operation was carried out. A Trans-femoral bypass was established before sternotomy. The Operative findings showed that adhesive connective tissue covered a pseudoaneurysm 8 cm by 4 cm in size, and that there was a tear in the anastomosis of the grafts between the ascending aorta and the arch 5 cm above the coronary ostia. Direct suture was performed, using hypothermic circulatory arrest. In this paper, we discuss the mechanism, classification, and operative strategy of traumatic pseudoaneurysm.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 145
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 44, 号 4, p. 145-147, 発行日 1995-12
旧ID 37875
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:31:44.573514
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3