Buckling of Transesophageal Echocardiography Probe : A pitfall at insertion in an anesthetized patient

https://hiroshima.repo.nii.ac.jp/records/2013334
https://hiroshima.repo.nii.ac.jp/records/2013334
cfb7cd1e-0344-4629-9e04-403a760fa090
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_42_155.pdf HiroshimaJMedSci_42_155.pdf (276.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Buckling of Transesophageal Echocardiography Probe : A pitfall at insertion in an anesthetized patient
言語 en
作成者 Orihashi, Kazumasa

× Orihashi, Kazumasa

en Orihashi, Kazumasa

Search repository
Sueda, Taijiro

× Sueda, Taijiro

en Sueda, Taijiro

Search repository
Matsuura, Yuichiro

× Matsuura, Yuichiro

en Matsuura, Yuichiro

Search repository
Yamanoue, Takao

× Yamanoue, Takao

en Yamanoue, Takao

Search repository
Yuge, Osafumi

× Yuge, Osafumi

en Yuge, Osafumi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Transesophageal echocardiography
主題
主題Scheme Other
主題 Complication
主題
主題Scheme Other
主題 Esophageal rupture
主題
主題Scheme Other
主題 Probe
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Buckling of the transesophageal echocardiography probe was encountered in 6 of 23 patients (26.1%), although no complication occurred. When buckling occurred, acquisition of images and manipulation of the probe became difficult, resistance was felt when withdrawal of the probe was attempted, and the probe was fixed in the extreme ante- or dorsiflexion. In this situation, the probe was carefully advanced into the stomach, in which the buckled probe was unfolded, and then withdrawn to the esophagus. Buckling of the probe tip is not uncommon at insertion of the probe, especially when using a flaccid probe in an anesthetized patient. A TEE operator should be aware of the possibility of buckling. Unusual resistance associated with buldging of the submandibular region is a sign of a folded-up probe tip. Use of laryngoscopy is recommended in order to avoid inserting the buckled probe into the esophagus.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 155
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 42, 号 4, p. 155-157, 発行日 1993-12
旧ID 37931
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:30:22.341457
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3