ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 40巻4号

Intraluminal Projection of Descending Thoracic Aorta and Intraaortic Balloon Pump Catheter Examined by Transesophageal Echocardiography in Patients Undergoing Coronary Artery Bypass Surgery

https://hiroshima.repo.nii.ac.jp/records/2013292
https://hiroshima.repo.nii.ac.jp/records/2013292
a4ddc9fd-04d6-4c3a-88fd-8791ee39fcff
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_40_119.pdf HiroshimaJMedSci_40_119.pdf (863.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Intraluminal Projection of Descending Thoracic Aorta and Intraaortic Balloon Pump Catheter Examined by Transesophageal Echocardiography in Patients Undergoing Coronary Artery Bypass Surgery
言語 en
作成者 Orihashi, Kazumasa

× Orihashi, Kazumasa

en Orihashi, Kazumasa

Search repository
Oka, Yasu

× Oka, Yasu

en Oka, Yasu

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Aorta
主題
主題Scheme Other
主題 Transesophageal echocardiography (TEE)
主題
主題Scheme Other
主題 Intraaortic balloon pump (IABP)
主題
主題Scheme NDC
主題 490
内容記述
内容記述 The thoracic descending aorta (DTA) was examined in 57 patients undergoing coronary artery bypass grafting (41 men and 16 women: 63.0 ± 10.6 years old) using two-dimensional transesophageal echocardiography. An intraaortic balloon pump (IABP) was instituted in ten patients. A short-axis view of DTA was examined for intraluminal projection from the diaphragm level to the aortic arch level. In a frozen-frame image, the area and the height of the projection at each clockwise direction was measured. Four patients with preoperative insertion of an IABP catheter were excluded from the analysis. Seventy projections were found in 40 of 53 patients (75.5%), most frequently found at the 3 to 6 o'clock position. The tip of the IABP catheter was also located in the area between 3 and 6 o'clock of the aortic lumen in 6 of 10 patients. In one case, the area of projection was reduced from 1.1 cm2 to 0.7 cm2. In two of four patients with preoperative institution of an IABP catheter, projections were found near the catheter tip.   Both intraluminal projections and IABP catheter tip were most commonly located in the same region of the DTA, suggesting a possible dislodging of the projection while advancing the catheter. This was demonstrated in one case. The catheter tip may damage the aortic intima and/or cause a formation of abnormal projection. We conclude that intraoperative examination of DTA in addition to routine monitoring can provide useful information which is helpful for minimizing complications at the time of insertion of an IABP catheter.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ PMID
関連識別子 1797742
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 119
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 40, 号 4, p. 119-126, 発行日 1991-12
旧ID 38025
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:29:09.289586
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3