WEKO3
アイテム
電量検出器を用いるイオン排除クロマトグラフ法による金属工業排水中のフッ化物イオンの定量
https://hiroshima.repo.nii.ac.jp/records/2011615
https://hiroshima.repo.nii.ac.jp/records/201161599d14961-5f28-40ee-892c-4feb4bd33760
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-18 | |||||||||
タイトル | ||||||||||
タイトル | 電量検出器を用いるイオン排除クロマトグラフ法による金属工業排水中のフッ化物イオンの定量 | |||||||||
言語 | ja | |||||||||
タイトル | ||||||||||
タイトル | Determination of fluoride ion in metal industry wastewaters by ion-exclusion chromatography with coulometric detection. | |||||||||
言語 | en | |||||||||
作成者 |
田中, 一彦
× 田中, 一彦
|
|||||||||
アクセス権 | ||||||||||
アクセス権 | open access | |||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | ion-exclusion chromatography with coulometric detection | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | cation exchange resin (H+-form) | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | determination of F- in metal industry wastewaters | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | methanol-water eluent | |||||||||
主題 | ||||||||||
主題Scheme | NDC | |||||||||
主題 | 430 | |||||||||
内容記述 | ||||||||||
内容記述 | 溶離液としてメタノール-水を用いるH+型陽イオン交換樹脂におけるイオン排除クロマトグラフ法により, 金属工業排水中のF-を定量した. 分離カラムから溶出したF-は, フッ化水素として導電率検出器及びH+が検出できる電量検出器(H+とp-ペンゾキノンの問の定電位電解反応)によりモニターした. 水溶離液を用いたとき, 強酸性陰イオン(Cl-)からのF-の分離は不完全であったが, 40%メタノール-水を用いる溶離により, 両者は完全に分離できた. メタノール-水を用いる溶離における両検出器応答の減少の程度は, 電量検出器のほうが小さかった. フッ化水素は弱酸であるため, 導電率検出器による検量線は非直線性を示したが, 電量検出器によるそれは少なくとも100ppmまで良好な直線性を示した. 以上の結果は, イオン排除クロマトグラフ法においては電量検出器が有効であることを示した. 本法により, アルミニウム精錬工業及びめっき工業排水中のF-の定量は, 良好に達成できた. | |||||||||
言語 | ja | |||||||||
内容記述 | ||||||||||
内容記述 | The ion-exclusion chromatography with a cation exchange resin (H+-form)using methanol-water mixture as an eluent was investigated for the determination of F- in several metal industry wastewaters. Fluoride ion eluted from the column was monitored with conductometric detector (COND) and flow coulometric detector (FCD) based on the electrochemical reaction of Ht ion from HF with p-benzoquinone at a constant applied potential (+0.45 V vs. Ag-AgI) . The retention volume (VR) of F- increased with increasing the concentration of methanol in the eluent, and that of very weak acid anion (HCO3-) decreased. Furthermore, the VR of strong acid anion (CI-) did not vary and corresponded to the column void volume. Thus, quantitative separation of F-from CI- and HCO3- was accomplished by elution with 40% (v/v) methanol-water. The COND responses of Cl-, F-, and HCO3- remarkably decreased with increasing the concentration of methanol. The FCD responses of Cl-, F-, and HCO3- did not remarkably decrease in comparison with the results obtained with the COND under the same elution conditions. This is most striking characteristics of the FCD. The calibration graph for F- obtained with the COND showed a nonlinear because of low dissociation at higher concentrations. However, the good linear relationship was obtained under the concentration range (5~100) ppm of F- with the FCD. Therefore, it is recommended to use the FCD in this method. The present method was applied to the determination of F- in several actual samples with satisfactory results. | |||||||||
言語 | en | |||||||||
出版者 | ||||||||||
出版者 | 日本分析化学会 | |||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
出版タイプ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 0525-1931 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | NCID | |||||||||
収録物識別子 | AN00222633 | |||||||||
開始ページ | ||||||||||
開始ページ | 439 | |||||||||
書誌情報 |
分析化学 分析化学 巻 32, 号 7, p. 439-443, 発行日 1983-07-05 |
|||||||||
旧ID | 29595 |