Experimental comparison of non-contact and tactile R-Test instruments in dynamic measurement

https://hiroshima.repo.nii.ac.jp/records/2008913
https://hiroshima.repo.nii.ac.jp/records/2008913
678934da-4316-44ad-af27-7c3e8b7081bc
名前 / ファイル ライセンス アクション
IJAMT_128_5277_.pdf IJAMT_128_5277_.pdf (5.2 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2024-11-29
タイトル
タイトル Experimental comparison of non-contact and tactile R-Test instruments in dynamic measurement
言語 en
作成者 Ibaraki, Soichi

× Ibaraki, Soichi

en Ibaraki, Soichi

Search repository
Onodera, Koki

× Onodera, Koki

en Onodera, Koki

Search repository
Jywe, Wen-Yuh

× Jywe, Wen-Yuh

en Jywe, Wen-Yuh

Search repository
Hsu, Chia-Ming

× Hsu, Chia-Ming

en Hsu, Chia-Ming

Search repository
Chang, Yu-Wei

× Chang, Yu-Wei

en Chang, Yu-Wei

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 en
権利情報 This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/s00170-023-12178-3
権利情報
言語 en
権利情報 This is not the published version. Please cite only the published version.
権利情報
言語 ja
権利情報 この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。
主題
言語 en
主題Scheme Other
主題 R-Test
主題
言語 en
主題Scheme Other
主題 Five-axis machine tools
主題
言語 en
主題Scheme Other
主題 Dynamic measurement
主題
言語 en
主題Scheme Other
主題 Geometric errors
内容記述
内容記述 The R-Test measures the three-dimensional displacement of a tool center point with respect to a work table in five-axis machine tool, as linear axes are driven synchronously with a rotary axis. This paper experimentally compares the measuring performance of the R-Test instruments with (1) tactile linear displacement sensors, (2) laser displacement sensors based on the refraction in a glass ball lens (Laser R-Test), and (3) laser interferometers, in dynamic tests described in ISO 10791- 6:2014. A tactile displacement sensor pushes its measuring contact to the target surface by a spring, and its stiffness can limit the measurement bandwidth. This paper experimentally investigates this influence in the measurement of dynamic synchronization error of rotary and linear axes particularly near the reversal point in the present tests. This paper also presents a test to measure the bandwidth of a tactile displacement sensor
言語 en
出版者
出版者 Springer Nature
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1007/s00170-023-12178-3
開始ページ
開始ページ 5277
書誌情報 en : The International Journal of Advanced Manufacturing Technology

巻 128, p. 5277-5288, 発行日 2023-09-07
旧ID 55822
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 04:38:50.560014
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3