タイトル | ||||||||||
タイトル | Self-calibration of rotary axis and linear axes error motions by an automated on-machine probing test cycle | |||||||||
言語 | en | |||||||||
作成者 |
Zimmermann, Nico
× Zimmermann, Nico
× Ibaraki, Soichi
|
|||||||||
アクセス権 | ||||||||||
アクセス権 | open access | |||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||
権利情報 | ||||||||||
権利情報 | This is not the published version. Please cite only the published version. この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。 | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Five-axis machine tool | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Touch trigger probe | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Error calibration | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Geometric error | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Self-calibration | |||||||||
主題 | ||||||||||
主題Scheme | Other | |||||||||
主題 | Error separation | |||||||||
内容記述 | ||||||||||
内容記述 | Efficient, precise and automated in-process calibration schemes are essential to improve the accuracy and productivity of five-axis machine tools. This paper presents a new calibration approach, which combines an on-machine measurement cycle and self-calibration techniques, to evaluate the position errors and the error motions of a rotary axis using a touch trigger probe and an uncalibrated cylindrical artefact. This significantly reduces the downtime of machine tools required for the calibration process. In contrast to many common calibration strategies for rotary axes of five-axis machine tools, the presented self-calibration concept does not neglect the positioning errors of the linear axes when identifying the position errors and the error motions of the rotary axis. The self-calibration procedure is able to separate the positioning errors of the linear axes in radial direction, and the radial error motions and the position errors of a rotary axis, as well as the errors related to the uncalibrated artefact. This error separation is realized by a test cycle consisting of four tests in which the measurements are conducted by particular axis movements. Furthermore, an uncertainty analysis of the self-calibration concept is conducted to visualize the uncertainty propagation within the mathematical model. The self-calibration procedure is analyzed by an experimental evaluation, which includes a comparison between the results of the self-calibration approach and an R-Test. This comparison shows that the results of both measurement procedures are consistent. | |||||||||
言語 | en | |||||||||
出版者 | ||||||||||
出版者 | Springer | |||||||||
言語 | ||||||||||
言語 | eng | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
出版タイプ | ||||||||||
出版タイプ | AO | |||||||||
出版タイプResource | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |||||||||
関連情報 | ||||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | 10.1007/s00170-020-05105-3 | |||||||||
関連情報 | ||||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | https://doi.org/10.1007/s00170-020-05105-3 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 0268-3768 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 1433-3015 | |||||||||
開始ページ | ||||||||||
開始ページ | 2107 | |||||||||
書誌情報 |
The International Journal of Advanced Manufacturing Technology The International Journal of Advanced Manufacturing Technology 巻 107, p. 2107-2120, 発行日 2020-03-14 |
|||||||||
旧ID | 51112 |