Sensitive determination of anions in saliva using capillary electrophoresis after transient isotachophoretic preconcentration

https://hiroshima.repo.nii.ac.jp/records/2008855
https://hiroshima.repo.nii.ac.jp/records/2008855
053b2b7d-cea6-4b0b-b8e9-27a4b5651aac
名前 / ファイル ライセンス アクション
Talanta_77_278.pdf Talanta_77_278.pdf (130.9 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Sensitive determination of anions in saliva using capillary electrophoresis after transient isotachophoretic preconcentration
言語 en
作成者 Xu, Zhongqi

× Xu, Zhongqi

en Xu, Zhongqi

Search repository
Doi, Takayuki

× Doi, Takayuki

en Doi, Takayuki

Search repository
Timerbaev, Andrei R.

× Timerbaev, Andrei R.

en Timerbaev, Andrei R.

Search repository
Hirokawa, Takeshi

× Hirokawa, Takeshi

en Hirokawa, Takeshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2008 Elsevier B.V.
主題
主題Scheme Other
主題 Inorganic anions
主題
主題Scheme Other
主題 Capillary zone electrophoresis
主題
主題Scheme Other
主題 Preconcentration
主題
主題Scheme Other
主題 Transient isotachophoresis
主題
主題Scheme Other
主題 Saliva
主題
主題Scheme NDC
主題 460
内容記述
内容記述 A transient isotachophoresis-capillary electrophoresis (tITP-CE) system for the determination of minor inorganic anions in saliva is described. The complete separation and quantification of bromide, iodide, nitrate, nitrite, and thiocyanate has been achieved with only centrifugation and dilution of the saliva sample. In-line tITP preconcentration conditions, created by introduction of the plugs of 5 mM dithionic acid (leading electrolyte) and 10 mM formic acid (terminating electrolyte) before and after the sample zone, respectively, allowed the limits of direct UV absorption detection (at 200 nm) to be up to 50-fold improved as compared with CE without tITP. As a result, nitrate and thiocyanate were still detectable at 4.6 and 3.8 µg l-1, respectively, in 1000 times diluted saliva. The daily variations of anionic concentrations in saliva samples taken from a smoking health volunteer were discussed based on the results of tITP-CE analysis. It was confirmed that the thiocyanate concentration in saliva noticeably increased after smoking. This is apparently the first report on simultaneous quantification of more than four anionic salivary constituents using CE.
言語 en
出版者
出版者 Elsevier Science BV
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1016/j.talanta.2008.06.017
関連情報
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1016/j.talanta.2008.06.017
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0039-9140
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00856594
開始ページ
開始ページ 278
書誌情報 Talanta
Talanta

巻 77, 号 1, p. 278-281, 発行日 2008-10-19
旧ID 25947
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 04:37:06.094362
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3