WEKO3
アイテム
Influence of the number of detectors by laser scattering method for estimation of particle size
https://hiroshima.repo.nii.ac.jp/records/2008762
https://hiroshima.repo.nii.ac.jp/records/20087620e7448b2-1e0a-406f-9aaa-a9b736a8d02f
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-18 | |||||||||
タイトル | ||||||||||
タイトル | Influence of the number of detectors by laser scattering method for estimation of particle size | |||||||||
言語 | en | |||||||||
作成者 |
Igushi, Tatsuo
× Igushi, Tatsuo
× Yoshida, Hideto
|
|||||||||
アクセス権 | ||||||||||
アクセス権 | open access | |||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||
権利情報 | ||||||||||
権利情報 | (c) 2012 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. | |||||||||
主題 | ||||||||||
主題Scheme | NDC | |||||||||
主題 | 540 | |||||||||
内容記述 | ||||||||||
内容記述 | Effect of the number of detectors on an inversion problem of a scattering pattern by laser scattering method based on Mie scattering model has been investigated. The influence of the number of detectors is obtained by comparing a given size distribution and a calculated size distribution by computer simulation and experimental method. An observing range of scattering angles is from 0.0007 to 2.5 rad. A non-linear iteration method is used for calculating particle size distribution. The number of detectors is changed from 6 to 81 elements by the computer simulation. The algorithm of the inversion problem is applied with mean diameters of log-normal distribution in a range from 0.546 to 214 μm at standard deviation of 0.27 and 0.68. Experimental results of certified mono-disperse polystyrene latex standards and a poly-disperse aluminum sample are obtained with 21, 41, and 81 elements detector, respectively. All tests are performed under conditions at diluted aqueous suspensions. Narrow size distribution is influenced by the number of detectors compared with wide size distribution. Not the number of physical detectors but the number of useful detectors affects the algorithm of the inversion problem. When the detector elements are over 20, the influence of the number of detectors is decreased. | |||||||||
言語 | en | |||||||||
出版者 | ||||||||||
出版者 | American Institute of Physics | |||||||||
言語 | ||||||||||
言語 | eng | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
出版タイプ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||
関連情報 | ||||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | 10.1063/1.4709493 | |||||||||
関連情報 | ||||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | http://dx.doi.org/10.1063/1.4709493 | |||||||||
関連情報 | ||||||||||
識別子タイプ | URI | |||||||||
関連識別子 | http://link.aip.org/link/?rsi/83/055103 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 0034-6748 | |||||||||
収録物識別子 | ||||||||||
収録物識別子タイプ | NCID | |||||||||
収録物識別子 | AA00817730 | |||||||||
開始ページ | ||||||||||
開始ページ | 055103 | |||||||||
書誌情報 |
Review of Scientific Instruments Review of Scientific Instruments 巻 83, 号 5, p. 055103, 発行日 2012 |
|||||||||
旧ID | 33946 |