ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文等

A self-calibration scheme to monitor long-term changes in linear and rotary axis geometric errors

https://hiroshima.repo.nii.ac.jp/records/2007692
https://hiroshima.repo.nii.ac.jp/records/2007692
df81649a-a771-472d-99c4-aafa91f02f1f
名前 / ファイル ライセンス アクション
Measurement_196_111183.pdf Measurement_196_111183.pdf (18.2 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-06-27
タイトル
タイトル A self-calibration scheme to monitor long-term changes in linear and rotary axis geometric errors
言語 en
作成者 Onishi, Shota

× Onishi, Shota

en Onishi, Shota

Search repository
Ibaraki, Soichi

× Ibaraki, Soichi

en Ibaraki, Soichi

Search repository
Kato, Tomoyasu

× Kato, Tomoyasu

en Kato, Tomoyasu

Search repository
Yamaguchi, Masashi

× Yamaguchi, Masashi

en Yamaguchi, Masashi

Search repository
Sugimoto, Takao

× Sugimoto, Takao

en Sugimoto, Takao

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 en
権利情報 © 2022. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報
言語 ja
権利情報 この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。
権利情報
言語 en
権利情報 This is not the published version. Please cite only the published version.
主題
言語 en
主題Scheme Other
主題 Geometric error
主題
言語 en
主題Scheme Other
主題 Five-axis machine tool
主題
言語 en
主題Scheme Other
主題 Touch-trigger probe
主題
言語 en
主題Scheme Other
主題 Self-calibration
主題
言語 en
主題Scheme Other
主題 Error separation
内容記述
内容記述 A calibration scheme of position and orientation errors of rotary axis average lines based on touch-trigger probing is widely available on many commercial five-axis machine tools. Such a measurement is influenced by error motions of both linear and rotary axes. This paper proposes a novel scheme to separately identify linear and rotary axis geometric errors by using a touch-trigger probe and an uncalibrated test piece. Whereas the proposed scheme is based on well-developed self-calibration schemes for the circularity measurement, an original contribution is that it is applied to separate linear and rotary axis geometric errors. Two case studies are presented. First, the proposed tests are performed on the same five-axis machine tool for half a year to observe a long-term change in linear and rotary axis geometric errors. The second case study investigates the influence of room temperature change on linear axis and rotary axis error motions.
言語 en
出版者
出版者 Elsevier
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.measurement.2022.111183
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 1873-412X
開始ページ
開始ページ 111183
書誌情報 en : Measurement

巻 196, p. 111183, 発行日 2022-04-16
旧ID 54004
備考 The full-text file will be made open to the public on 16 Apr 2024 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 04:00:06.607194
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3