ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文等

Dimensional stability and weight changes of tissue conditioners

https://hiroshima.repo.nii.ac.jp/records/2007441
https://hiroshima.repo.nii.ac.jp/records/2007441
d2f11cbe-0031-4b3e-a872-57cc7f5530a9
名前 / ファイル ライセンス アクション
JOralRehabil_28-10_918.pdf JOralRehabil_28-10_918.pdf (563.1 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Dimensional stability and weight changes of tissue conditioners
言語 en
作成者 Murata, Hiroshi

× Murata, Hiroshi

en Murata, Hiroshi

Search repository
Kawamura, Mayumi

× Kawamura, Mayumi

en Kawamura, Mayumi

Search repository
Hamada, Taizo

× Hamada, Taizo

en Hamada, Taizo

Search repository
Saleh, S.

× Saleh, S.

en Saleh, S.

Search repository
Kresnoadi, U.

× Kresnoadi, U.

en Kresnoadi, U.

Search repository
Toki, Kazuhito

× Toki, Kazuhito

en Toki, Kazuhito

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2001 Blackwell Publishing. The definitive version is available at www.blackwell-synergy.com
内容記述
内容記述 The dimensional stability of tissue conditioners characterizes the ability of the materials to yield accurate functional impressions of oral mucosa. This study evaluated the linear dimensional changes with time of six tissue conditioners (COE Comfort, FITT, GC Soft-Liner, Hydro-Cast, SR-Ivoseal and Visco-Gel) using a travelling microscope, and relationship between these changes and weight changes. The absorption and solubility of these materials were also determined. The percentage changes in dimension and weight in water storage were measured at 2 (baseline), 8 and 24 h, and 2, 4, 7, 14 and 21 days after specimen preparation. All materials except SR-Ivoseal exhibited shrinkage and weight loss during water storage, whilst SR-Ivoseal exhibited expansion and an increase in weight. The percentage solubility for all materials except SR-Ivoseal was higher than the percentage absorption. A positive linear relationship was found between the percentage changes in linear dimension and those in weight (r=0·797 - 0·986, P < 0·05). Water absorption and solubility of the materials were found to be associated with dimensional changes. The results suggest that the period recommended for forming functional impressions would be 24 h after insertion in the mouth. In addition, it is important to select tissue conditioners suitable for functional impressions because of the wide ranges of dimensional stability among the materials.
言語 en
出版者
出版者 Blackwell Publishing
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1046/j.1365-2842.2001.00736.x
関連情報
識別子タイプ PMID
関連識別子 11737562
関連情報
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1046/j.1365-2842.2001.00736.x
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0305-182X
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00704042
開始ページ
開始ページ 918
書誌情報 Journal of Oral Rehabilitation
Journal of Oral Rehabilitation

巻 28, 号 10, p. 918-923, 発行日 2001-10
旧ID 20335
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:52:07.693785
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3