WEKO3
アイテム
Measurement of the flood discharge of a small-sized river using an existing digital video recording system
https://hiroshima.repo.nii.ac.jp/records/2007355
https://hiroshima.repo.nii.ac.jp/records/2007355375a21c4-273d-4c8f-b852-8a0373c4dc75
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-18 | |||||||||||
タイトル | ||||||||||||
タイトル | Measurement of the flood discharge of a small-sized river using an existing digital video recording system | |||||||||||
言語 | en | |||||||||||
作成者 |
Tsubaki, Ryota
× Tsubaki, Ryota
× Fujita, Ichiro
× Tsutsumi, Shiho
|
|||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
権利情報 | ||||||||||||
権利情報 | (c) 2011 International Association of Hydro-environment Engineering and Research, Asia Pacific Division. Published by Elsevier B.V. All rights reserved. | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | LSPIV | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | STIV | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | Small-sized river | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | CCTV | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | River discharge measurement | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | Float method | |||||||||||
主題 | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | Floating debris | |||||||||||
主題 | ||||||||||||
主題Scheme | NDC | |||||||||||
主題 | 510 | |||||||||||
内容記述 | ||||||||||||
内容記述 | In this study, a closed-circuit television (CCTV) system, installed for surveillance purposes, is utilized to measure the flow rate during a flood. The procedure to determine both the angle and scale-factor of the camera is described. Then, image analysis techniques, namely the direct visual measurement method, Large-Scale PIV (LSPIV) and Space-Time Image Velocimetry (STIV), are applied to the video images recorded by the CCTV camera. The results of these methods and the conventional float measurement are compared. In addition, the accuracy of the respective methods is discussed. A set of low-quality video images of a flood during a thunderstorm that occurred under the dark ambient conditions (midnight) is analyzed using three image-based methods. The transition of the flow rate during the event is successfully estimated. | |||||||||||
言語 | en | |||||||||||
出版者 | ||||||||||||
出版者 | Elsevier Science BV | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | journal article | |||||||||||
出版タイプ | ||||||||||||
出版タイプ | AO | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |||||||||||
関連情報 | ||||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | 10.1016/j.jher.2010.12.004 | |||||||||||
関連情報 | ||||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | http://dx.doi.org/10.1016/j.jher.2010.12.004 | |||||||||||
収録物識別子 | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 1570-6443 | |||||||||||
収録物識別子 | ||||||||||||
収録物識別子タイプ | NCID | |||||||||||
収録物識別子 | AA1224925X | |||||||||||
開始ページ | ||||||||||||
開始ページ | 313 | |||||||||||
書誌情報 |
Journal of Hydro-environment Research Journal of Hydro-environment Research 巻 5, 号 4, p. 313-321, 発行日 2011 |
|||||||||||
旧ID | 34825 |