ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文等

Enhancement of cryptosporidium oocyst removal by coagulation and sedimentation with poly-silicate iron (PSI)

https://hiroshima.repo.nii.ac.jp/records/2007251
https://hiroshima.repo.nii.ac.jp/records/2007251
3d2989f5-8c3f-40ef-a298-048e83fc4479
名前 / ファイル ライセンス アクション
JCEJ_39_137.pdf JCEJ_39_137.pdf (228.3 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Enhancement of cryptosporidium oocyst removal by coagulation and sedimentation with poly-silicate iron (PSI)
言語 en
作成者 Okuda, Tetsuji

× Okuda, Tetsuji

en Okuda, Tetsuji

Search repository
Deevanhxay, Phengxay

× Deevanhxay, Phengxay

en Deevanhxay, Phengxay

Search repository
Nishijima, Wataru

× Nishijima, Wataru

en Nishijima, Wataru

Search repository
Hasegawa, Takako

× Hasegawa, Takako

en Hasegawa, Takako

Search repository
Okada, Mitsumasa

× Okada, Mitsumasa

en Okada, Mitsumasa

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2006 The society of chemical engineers, Japan
主題
主題Scheme Other
主題 Coagulant
主題
主題Scheme Other
主題 Crypto-Tracer
主題
主題Scheme Other
主題 Flocculation Performance
主題
主題Scheme Other
主題 Sedimentation
主題
主題Scheme Other
主題 Synthetic Cryptosporidium Oocyst
主題
主題Scheme NDC
主題 570
内容記述
内容記述 The improvement of Cryptosporidium oocysts removals is an urgent need in drinking water treatment and one of the possible solutions is to use high-performance coagulant such as poly-silicate iron coagulant (PSI) instead of conventional coagulants like poly aluminum chloride (PAC). The efficiency of synthetic Cryptosporidium oocysts (S-Crypto) removal using PSI was evaluated by both jar tests and pilot plant experiments. The residual concentration of S-Crypto could be reduced even though the coagulation was operated under the optimum conditions for turbidity removal. The removal efficiencies of S-Crypto using PSI were up to 42-1073766880gher than those using PAC in the pilot plant. The higher performance of PSI is brought about by the presence of ferric species in the coagulant which promotes better sedimentation and not by the higher flocculation performance of the coagulant. In addition, the performance of PSI was independent of temperature, and S-Crypto removal by ferric chloride (FC) was not stable in cold raw water. It was suspected that the bound polymerized silica of PSI increases the stability of coagulation in cold water.
言語 en
出版者
出版者 The society of chemical engineers, Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1252/jcej.39.137
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 http://dx.doi.org//10.1252/jcej.39.137
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00709658
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0021-9592
開始ページ
開始ページ 137
書誌情報 Journal of Chemical Engineering of Japan
Journal of Chemical Engineering of Japan

巻 39, 号 2, p. 137-143, 発行日 2006
旧ID 24974
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:46:18.603411
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3