The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements |
|
言語 |
en |
作成者 |
Horiguchi, Jun
Fukuda, Hiroshi
Yamamoto, Hideya
Hirai, Nobuhiko
Alam, Farzana
Kakizawa, Hideaki
Hieda, Masashi
Tachikake, Toshihiro
Marukawa, Kazushi
Ito, Katsuhide
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
権利情報 |
|
|
権利情報 |
Copyright (c) 2007 Springer "The original publication is available at www.springerlin.com" |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Cardiac |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Coronary artery |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Calcification |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
CT |
主題 |
|
|
主題Scheme |
NDC |
|
主題 |
490 |
内容記述 |
|
|
内容記述 |
The purpose of this study is, using a 16-section multidetector-row helical computed tomography (MDCT) scanner with retrospective reconstruction, to compare variability in repeated coronary calcium scoring and qualitative scores of the motion artifacts. One hundred forty-four patients underwent two subsequent scans using MDCT. According to Agatston and volume algorithms, the coronary calcium scores during mid-diastole (the center corresponding to 700f the R-R cycle) were calculated and the inter-scan variability was obtained. Motion artifacts from coronary artery calcium were subjectively evaluated and classified using a 5-point scale: 1, excellent; no motion artifacts; 2, fine, minor motion artifacts; 3, moderate, mild motion artifacts; 4, bad, severe motion artifacts; 5, poor, doubling or discontinuity. Each reading was done by vessels (left main, left descending, left circumflex and right coronary arteries) and the motion artifact score (mean of the scales) was determined per patient. The variability in the low (1.2±0.2) and high (2.4±0.6) motion artifact score groups was 7±6 (median, 6)-0x1.4aa00bfffbf7p-149nd 19±15 (16)26651131640n the Agatston score (P<0.01) and 7±7 (6)-0x1.f9a280852f11p+0nd 16±13 (14)26646061170n the volume score (P<0.01), respectively. In conclusion, motion has a significant impact on the reproducibility of coronary calcium scoring. |
|
言語 |
en |
出版者 |
|
|
出版者 |
Springer |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
出版タイプ |
|
|
出版タイプ |
AO |
|
出版タイプResource |
http://purl.org/coar/version/c_b1a7d7d4d402bcce |
関連情報 |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.1007/s00330-006-0278-2 |
関連情報 |
|
|
|
識別子タイプ |
PMID |
|
|
関連識別子 |
16718452 |
関連情報 |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
http://dx.doi.org/10.1007/s00330-006-0278-2 |
収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0938-7994 |
収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA10824302 |
開始ページ |
|
|
開始ページ |
81 |
書誌情報 |
European Radiology
European Radiology
巻 17,
号 1,
p. 81-86,
発行日 2007-01
|
旧ID |
20581 |