  1. 学術雑誌論文等

Reciprocating-flow ATP amplification system for increasing the number of amplification cycles

https://hiroshima.repo.nii.ac.jp/records/2006211
https://hiroshima.repo.nii.ac.jp/records/2006211
531014ac-a178-481e-b2e9-9e186c96b41b
名前 / ファイル ライセンス アクション
AnalBiochem_395_161.pdf AnalBiochem_395_161.pdf (1.3 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Reciprocating-flow ATP amplification system for increasing the number of amplification cycles
言語 en
作成者 Satoh, Tetsuya

× Satoh, Tetsuya

en Satoh, Tetsuya

Search repository
Tsuruta, Kosuke

× Tsuruta, Kosuke

en Tsuruta, Kosuke

Search repository
Shinoda, Yasuharu

× Shinoda, Yasuharu

en Shinoda, Yasuharu

Search repository
Hirota, Ryuichi

× Hirota, Ryuichi

en Hirota, Ryuichi

Search repository
Noda, Kenichi

× Noda, Kenichi

en Noda, Kenichi

Search repository
Kuroda, Akio

× Kuroda, Akio

en Kuroda, Akio

Search repository
Murakami, Yuji

× Murakami, Yuji

en Murakami, Yuji

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2009 Elsevier Inc.
主題
主題Scheme Other
主題 ATP amplification
主題
主題Scheme Other
主題 Reciprocating-flow system
主題
主題Scheme Other
主題 Bioluminescence assay
主題
主題Scheme NDC
主題 460
内容記述
内容記述 We constructed a novel ATP amplification reactor using a reciprocating-flow system to increase the number of ATP amplification cycles without an increase in backpressure. We previously reported a continuous-flow ATIP amplification system that effectively and quantitatively amplified ATP and increased the sensitivity of a quantitative bioluminescence assay. However, it was difficult to increase the number of amplification cycles due to backpressure in the system. Because addition of immobilized adenylate kinase (ADK) and pyruvate kinase (PK) columns increased backpressure, the maximum number of ATP amplification cycles within Column durability was only 4. In this Study, ATP amplification was performed using a reciprocating-flow system, and 10 cycles of ATP amplification could be achieved without an increase in backpressure. As a result, ATP was amplified more than 100-fold after 10 cycles of reciprocating flow. The gradient of ATP amplification was approximately 1.76(N). The backpressure oil the columns was 0.03 MPa in 1-10 ATIP amplification cycles, and no increases in backpressure were observed.
言語 en
出版者
出版者 Academic Press INC
出版者
出版者 Elsevier Science
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1016/j.ab.2009.08.025
関連情報
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1016/j.ab.2009.08.025
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0003-2697
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00524867
開始ページ
開始ページ 161
書誌情報 Analytical Biochemistry
Analytical Biochemistry

巻 395, 号 2, p. 161-165, 発行日 2009-12-15
旧ID 28856
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:14:13.198674
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3