ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文等

Evaluation of Inappropriate Positioning of Dosimeters in Medical Workers Based on Dose Equivalent Hp (10)

https://hiroshima.repo.nii.ac.jp/records/2040500
https://hiroshima.repo.nii.ac.jp/records/2040500
0474771e-241f-4dd2-be1d-061e1a1ee61d
名前 / ファイル ライセンス アクション
HP_124_1_10.docx HP_124_1_10.docx (215.6 MB)
Item type デフォルト(1)
公開日 2025-05-01
タイトル
タイトル Evaluation of Inappropriate Positioning of Dosimeters in Medical Workers Based on Dose Equivalent Hp (10)
言語 en
作成者 Tamura, Megumi

× Tamura, Megumi

en Tamura, Megumi

Search repository
Kawamoto, Takeshi

× Kawamoto, Takeshi

en Kawamoto, Takeshi

Search repository
Kenjo, Masahiro

× Kenjo, Masahiro

en Kenjo, Masahiro

Search repository
Nakashima, Takeo

× Nakashima, Takeo

en Nakashima, Takeo

Search repository
Kawano, Reo

× Kawano, Reo

en Kawano, Reo

Search repository
Tamura, Takayuki

× Tamura, Takayuki

en Tamura, Takayuki

Search repository
Ishifuro, Minoru

× Ishifuro, Minoru

en Ishifuro, Minoru

Search repository
Kiguchi, Masao

× Kiguchi, Masao

en Kiguchi, Masao

Search repository
Awai, Kazuo

× Awai, Kazuo

en Awai, Kazuo

Search repository
Nagata, Yasushi

× Nagata, Yasushi

en Nagata, Yasushi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 en
権利情報 This is a pre-copyedited, author-produced version of an article accepted for publication in [Health Physics]. The published version of record [Tamura, Megumi1; Kawamoto, Takeshi2; Kenjo, Masahiro3; Nakashima, Takeo1; Kawano, Reo4; Tamura, Takayuki1; Ishifuro, Minoru5; Kiguchi, Masao1; Awai, Kazuo6; Nagata, Yasushi7. Evaluation of Inappropriate Positioning of Dosimeters in Medical Workers Based on Dose Equivalent Hp(10). Health Physics 124(1):p 10-16, January 2023. | DOI: 10.1097/HP.0000000000001619 ] is available online at https://doi.org/10.1097/HP.0000000000001619
権利情報
言語 en
権利情報 This is not the published version. Please cite only the published version.
権利情報
言語 ja
権利情報 この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。
主題
言語 en
主題Scheme Other
主題 dose equivalent
主題
言語 en
主題Scheme Other
主題 dosimetry
主題
言語 en
主題Scheme Other
主題 errors
主題
言語 en
主題Scheme Other
主題 effective dose
主題
言語 en
主題Scheme Other
主題 radiation protection
内容記述
内容記述タイプ Abstract
内容記述 This report presents a new method to characterize the inappropriate positioning of dosimeters based on the dose equivalent Hp (10). The Hp (10) values of medical workers were measured monthly for 12 mo using two personal dosimeters. Using the ratio between the values of Hp(10) recorded from dosimeters worn over and under protective aprons [Hp(10)over and Hp(10)under, respectively], 670 pairs of dosimeter readings were categorized into a proper use group [Hp(10)over/Hp(10)under ≥ 5] and a misuse group [Hp(10)over/Hp(10)under < 5]. Following personal interviews, the readings in the misuse group were classified into the following six subgroups: “reversed,” “sometimes reversed,” “both under,” “both over,” “without apron,” and “not specified.” Ultimately, the scatter plot of “Hp (10) over – Hp (10) under” vs. Hp (10) over was identified as the most promising tool for clarifying the misuse patterns of dosimeters, as individual readings were mapped to the locations of the corresponding subgroups in the obtained graphs. Our results are expected to facilitate efficient and accurate usage of dosimeters by medical workers.
言語 en
出版者
出版者 Lippincott, Williams & Wilkins
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1097/HP.0000000000001619
助成情報
助成機関識別子タイプ Crossref Funder
助成機関識別子タイプURI https://doi.org/10.13039/501100001691
助成機関名 日本学術振興会
言語 ja
助成機関名 Japan Society for the Promotion of Science
言語 en
研究課題番号URI https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-18K10003/
研究課題番号 18K10003
研究課題名 RFID技術を活用した個人線量計装着検知システムの構築
言語 ja
研究課題名 Construction of wearing detection system for personal dosemeters using RFID technology
言語 en
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0017-9078
書誌情報 en : Health Physics

巻 124, 号 1, p. 10-16, ページ数 7, 発行日 2023-01
戻る
0
views
See details
Views

Versions

Ver.1 2025-05-01 05:19:44.461405
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3