脳深部刺激療法を留置したパーキンソン病患者の脊髄くも膜下麻酔中にウエアリングオフ様症状と自律神経反射亢進症状を合併した1症例

https://hiroshima.repo.nii.ac.jp/records/2036418
https://hiroshima.repo.nii.ac.jp/records/2036418
7761b5ca-7a9d-4c0a-922a-226e4f527c88
名前 / ファイル ライセンス アクション
AnesthResus_55-1_39.pdf AnesthResus_55-1_39.pdf (1.8 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル 脳深部刺激療法を留置したパーキンソン病患者の脊髄くも膜下麻酔中にウエアリングオフ様症状と自律神経反射亢進症状を合併した1症例
言語 ja
タイトル
タイトル A Case of a Combination of Wearing-Off-Like Symptoms and Autonomic Hyperreflexia Following Spinal Anesthesia for a Patient with Parkinson’s Disease Who is Treated by Deep Brain Stimulation
言語 en
作成者 田嶋, 実

× 田嶋, 実

ja 田嶋, 実

en Tajima, Minoru

Search repository
柳谷, 忠雄

× 柳谷, 忠雄

ja 柳谷, 忠雄

en Yanagidani, Tadao

Search repository
松浪, 勝昭

× 松浪, 勝昭

ja 松浪, 勝昭

en Matunami, Katsuaki

Search repository
近藤, 洋司

× 近藤, 洋司

ja 近藤, 洋司

en Kondh, Hiroshi

Search repository
笹田, 将吾

× 笹田, 将吾

ja 笹田, 将吾

en Sasada, Syogo

Search repository
彌久末, 智子

× 彌久末, 智子

ja 彌久末, 智子

en Yakusue, Tomoko

Search repository
永島, 健太

× 永島, 健太

ja 永島, 健太

en Nagashima, Kenta

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 パーキンソン病
主題
主題Scheme Other
主題 脳深部刺激療法
主題
主題Scheme Other
主題 脊髄幹麻酔
主題
主題Scheme Other
主題 合併症
主題
主題Scheme Other
主題 Parkinson’s disease
主題
主題Scheme Other
主題 Deep brain stimulation
主題
主題Scheme Other
主題 neuraxial analgesia
主題
主題Scheme Other
主題 complications
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Deep brain stimulator (DBS) has been widely performed for various medically refractory movement disorders. We report a 70’s male patients with Parkinson’s disease (PD) treated by DBS in addition to anti-parkinsonian drugs who underwent transurethral lithotomy under spinal anesthesia twice. We canceled his usual medications for PD, therefore, his blood pressure was higher than usual. His DBS was turned off in the operation room before induction of anesthesia. Both anesthesia techniques for TUL surgeries were completed by spinal anesthesia used by 0.5% hyperbaric bupivacine. Immediately after spinal anesthesia in both surgeries, severe rigidity, airway obstruction and conscious change emerged. These complications were suspected wearing-off-likes symptoms of PD, which were proved because of spinal anesthesia itself and/or DBS off effects. Autonomic hyperreflexia with severe hypertension, abnormal sweating and excessive oral secretion was gradually appeared after infusion of normal saline to obtain surgical fields of view, however, these symptoms disappeared after the end of infusion. It was suspected that the adverse events were due to low effects of spinal anesthesia on autonomic nervous system degenerated by Parkinson’s disease. We turned on DBS immediately after the completion of surgeries, and resumed his oral medications on the next day of surgeries. There were no events in his courses. As there is little information and no standard anesthetic guidelines available on patients with DBS implant who are present for surgery, a careful management is needed to avoid complications.
言語 en
内容記述
内容記述タイプ Other
内容記述 本稿の要旨は日本麻酔科学会 中国・四国支部第55回学術集会(松山市,2018年)で発表した。
出版者
出版者 広島麻酔医学会
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0385-1664
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AN00232251
開始ページ
開始ページ 39
書誌情報 麻酔と蘇生
Ansesthesia and Resuscitation

巻 55, 号 1, p. 39-43, 発行日 2019-03-01
見出し
大見出し 臨床研究
言語 ja
見出し
大見出し 臨床研究
言語 en
旧ID 47563
戻る
0
views
See details
Views

Versions

Ver.1 2025-03-03 10:55:52.450495
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3