Comparison of astigmatism in three-year-old children with epiblepharon who underwent closer examination in a vision screening program |
|
言語 |
en |
| 作成者 |
KABURA, Ryota
IWASAKI, Rumi
FUKUDA, Rikako
MATSUMOTO, Kanon
FURUSHIMA, Kyoka
TAKESHITA, Tetsuji
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 権利情報 |
|
|
言語 |
en |
|
権利情報 |
Copyright (c) 2023 Hiroshima University Medical Press |
| 主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Vision screening program |
| 主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Epiblepharon |
| 主題 |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Astigmatism |
| 内容記述 |
|
|
内容記述 |
This study aimed to compare 3-year-old children with suspected astigmatism and refractive errors in a vision screening program (VSP) and those diagnosed with epiblepharon on closer examination (CE). In a population of 1,250 children in a VSP conducted between April 2014 and March 2021, 168 children received a CE rating, and 89 patients subsequently underwent CE. The handheld refractors used in VSP were SureSight® and Spot®VisionScreener (Welch Allyn). In CE, a 5 m Landolt C ring angular vision test and auto-ref/keratometer TONOREFTM II (NIDEK) was used for measurement in non-cycloplegia. Epiblepharon was diagnosed by an ophthalmologist using slit-lamp microscopy. The patients were divided into epiblepharon and non-epiblepharon groups for CE. VSP detected a cylindrical power of 1.65 ± 2.25 D and 0.86 ± 0.74 D, respectively, in the epiblepharon and without epiblepharon groups. CE detected an uncorrected visual acuity of 0.42 ± 0.46 and 0.16 ± 0.29 (logMAR), a corrected visual acuity of 0.22 ± 0.31 and 0.09 ± 0.24, a subjective cylindrical power of 0.65 ± 1.15 D and 0.23 ± 0.56 D, and corneal astigmatism of 1.97 ± 0.93 D and 1.45 ± 0.82 D in the epiblepharon and without epiblepharon groups, respectively; significant differences were observed for all parameters (p < 0.05). Among 3-year-old children with suspected amblyopia or refractive error not reaching the reference level, those with epiblepharon had more astigmatism than those without it. If a case of high astigmatism is found in the refractive test, an epiblepharon may be present. |
|
言語 |
en |
| 内容記述 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
The findings were briefly presented in part as an oral presentation (#P-29) at the 62nd Annual Meeting of the Japanese Orthoptic Congress, Chiyoda-ku, Tokyo, Japan on November 20, 2021. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Hiroshima University Medical Press |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
| 出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| 関連情報 |
|
|
関連タイプ |
isIdenticalTo |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.24811/hjms.72.1-2_5 |
| 開始ページ |
|
|
開始ページ |
5 |
| 書誌情報 |
en : Hiroshima Journal of Medical Sciences
巻 72,
号 1-2,
p. 5-9,
ページ数 5,
発行日 2023-06
|
| 旧ID |
54943 |