Basic performance assessment of reagents for measuring soluble FMS-like tyrosine kinase 1 (sFlt-1) and placental growth factor (PlGF) in Japanese women

https://hiroshima.repo.nii.ac.jp/records/2013816
https://hiroshima.repo.nii.ac.jp/records/2013816
ab92e310-2bea-485d-9326-4ed99fa9c96d
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_71_51.pdf HiroshimaJMedSci_71_51.pdf (290.2 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Basic performance assessment of reagents for measuring soluble FMS-like tyrosine kinase 1 (sFlt-1) and placental growth factor (PlGF) in Japanese women
言語 en
作成者 NISHIHARA, Haruna

× NISHIHARA, Haruna

en NISHIHARA, Haruna

Search repository
YAMAZAKI, Shinichi

× YAMAZAKI, Shinichi

en YAMAZAKI, Shinichi

Search repository
ARASE, Takashi

× ARASE, Takashi

en ARASE, Takashi

Search repository
YAMAZAKI, Tomomi

× YAMAZAKI, Tomomi

en YAMAZAKI, Tomomi

Search repository
KUDO, Yoshiki

× KUDO, Yoshiki

en KUDO, Yoshiki

Search repository
YOKOZAKI, Michiya

× YOKOZAKI, Michiya

en YOKOZAKI, Michiya

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2022 Hiroshima University Medical Press
主題
主題Scheme Other
主題 sFlt-1
主題
主題Scheme Other
主題 PlGF
主題
主題Scheme Other
主題 hypertensive disorders of pregnancy
主題
主題Scheme Other
主題 preeclampsia
内容記述
内容記述 Among the factors associated with angiogenesis, soluble FMS-like tyrosine kinase-1 (sFlt-1) is antiangiogenic and placental growth factor (PlGF) is proangiogenic. The sFlt-1/PlGF ratio is considered useful for the short-term prediction of preeclampsia (PE) in high-risk pregnancies and has been used clinically in Japan since July 2021. Regarding the clinical use of the sFlt-1/PlGF ratio in Japan, there have been no published reports demonstrating that sFlt-1 and PlGF assay reagents have the same basic performance in Japanese and European women. To our knowledge, we conducted the first basic performance assessment of the sFlt-1 and PlGF assay reagents using sera from Japanese women. We obtained satisfactory results for repeatability, intermediate precision, linearity, effects of interferents, and the LoQ. The sFlt-1 and PlGF assay reagents performed well, and we believe that they are entirely adequate for use in routine clinical assays of Japanese patients, similar to those in European patients.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 2433-7668
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 51
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 71, 号 3-4, p. 51-55, 発行日 2022-12
旧ID 53497
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:44:35.660049
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3