| Item type |
デフォルトアイテムタイプ_(フル)(1) |
| 公開日 |
2023-03-18 |
| タイトル |
|
|
タイトル |
Accuracy management survey of nucleic acid amplification tests using inactivated SARS-CoV-2 in Hiroshima Prefecture |
|
言語 |
en |
| 作成者 |
NOMURA, Toshihito
NAZMUL, Tanuza
HIGASHIURA, Akifumi
SHIGEMOTO, Naoki
ARIYOSHI, Kunie
KITAGAWA, Hiroki
OMORI, Keitaro
SHIGEMOTO, Norihumi
KUWABARA, Masao
KO, Ko
TANAKA, Junko
TAHARA, Hidetoshi
OHDAN, Hideki
KUBO, Tatsuhiko
OHGE, Hiroki
SAKAGUCHI, Takemasa
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 権利情報 |
|
|
権利情報 |
Copyright (c) 2022 Hiroshima University Medical Press |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
COVID-19 |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Laboratory Test |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
RT-qPCR |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
LAMP |
| 内容記述 |
|
|
内容記述 |
At the beginning of 2020, the number of laboratories performing SARS-CoV-2 testing increased with the rapid expansion of COVID-19 in Hiroshima Prefecture. Thus, it is necessary to compare and verify the validity of the test results among local laboratories. In this study, we distributed the same standard samples to laboratories that performed COVID-19 testing using the nucleic acid amplification method and confirmed the accuracy of the tests. The SARS-CoV-2 strain distributed by the National Institute of Infectious Diseases (NIID), Japan, was used for testing. As measured by RT-qPCR, a specific amount of the virus was inactivated by ethanol and dried as specimens for distribution. This study included 27 tests performed at 15 laboratories conducting or planning to conduct nucleic acid amplification tests (RT-qPCR and LAMP methods) for SARSCoV-2. The detection limit of each test method was set at the value provided by the NIID. The accuracy of the tests was examined to determine whether they met the required accuracy criteria. SARS-CoV-2 genomic RNA was reliably detected in all 27 tests. The inactivated specimens used in this study were safe to distribute and could be used as positive controls for all methods. |
|
言語 |
en |
| 内容記述 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
This study was supported by a grant from the Government-Academia Collaboration of Hiroshima Prefecture and by a research grant for COVID-19 from AMED, Japan under Grant Number 20he0622011h0001(to J. T.). |
| 出版者 |
|
|
出版者 |
Hiroshima University Medical Press |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
| 出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0018-2052 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
2433-7668 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00664312 |
| 開始ページ |
|
|
開始ページ |
39 |
| 書誌情報 |
Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences
巻 71,
号 3-4,
p. 39-43,
発行日 2022-12
|
| 旧ID |
53495 |