| Item type |
デフォルトアイテムタイプ_(フル)(1) |
| 公開日 |
2023-03-18 |
| タイトル |
|
|
タイトル |
Computed Tomography Fluoroscopy-guided Biopsy of Lung Nodules: Comparison of the Step-wise and Realtime Techniques |
|
言語 |
en |
| 作成者 |
KAJIWARA, Kenji
MURAKAMI, Kaho
MAEDA, Hitomi
YOSHIMATSU, Rika
YAMANISHI, Tomoaki
MINAMIGUCHI, Hiroki
AWAI, Kazuo
YAMAGAMI, Takuji
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 権利情報 |
|
|
権利情報 |
Copyright (c) 2021 Hiroshima University Medical Press |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Non-vascular intervention |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Lung biopsy |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
CT fluoroscopy |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Step-wise technique |
| 内容記述 |
|
|
内容記述 |
The present study aimed to compare the step-wise and real-time techniques for computed tomography (CT) fluoroscopy-guided biopsy of lung nodules. It included 72 consecutive patients (50 men, 22 women; mean age: 71.8 years; range: 45–89 years) with lung nodules. Between March 2017 and April 2019, 72 CT fluoroscopy-guided biopsy procedures were performed using either the step-wise (n = 34) or real-time technique (n = 38). The diagnostic accuracy was 97.1% for biopsies performed using the step-wise technique and 94.7% for those performed using the real-time technique (p = 0.39). The mean CT dose index was 48.8 ± 16.9 mGy/s for the step-wise method and 59.9 ± 25.6 mGy/s for the real-time method; the dose length product was 1956 ± 729 mGy and 2613 ± 1300 mGy for the two techniques, respectively (p < 0.05). There was a significant difference in mean exposure time (81 ± 43 s for the step-wise technique and 162 ± 120 s for the real-time technique; p < 0.05). The mean lung nodule size was also significantly different (29.9 ± 17.6 mm for the step-wise method and 17.8 ± 12.2 mm for the real-time method; p < 0.01). Of the 34 step-wise procedures, 11 (32.4%) resulted in pneumothorax, as did 24 of 38 (63.2%) real-time procedures (p < 0.01). The real-time technique is particularly useful in patients with small nodules. The CT dose, exposure time, and incidence of pneumothorax were significantly lower when the step-wise technique was applied to CT fluoroscopy-guided biopsy of lung nodules. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Hiroshima University Medical Press |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
| 出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| 関連情報 |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.24811/hjms.70.2-4_35 |
| 関連情報 |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.24811/hjms.70.2-4_35 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0018-2052 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
2433-7668 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00664312 |
| 開始ページ |
|
|
開始ページ |
35 |
| 書誌情報 |
Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences
巻 70,
号 2-4,
p. 35-38,
発行日 2021-12
|
| 旧ID |
51912 |