Short-Term Results of Thoracic Endovascular Aortic Repair for Aortic Arch Aneurysm with a Fenestrated Stent Graft

https://hiroshima.repo.nii.ac.jp/records/2013806
https://hiroshima.repo.nii.ac.jp/records/2013806
0bb6a344-4963-4927-9613-8d448af1a914
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_70_27.pdf HiroshimaJMedSci_70_27.pdf (9.6 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Short-Term Results of Thoracic Endovascular Aortic Repair for Aortic Arch Aneurysm with a Fenestrated Stent Graft
言語 en
作成者 SATO, Katsutoshi

× SATO, Katsutoshi

en SATO, Katsutoshi

Search repository
EMURA, Shogo

× EMURA, Shogo

en EMURA, Shogo

Search repository
TOMIYOSHI, Hideki

× TOMIYOSHI, Hideki

en TOMIYOSHI, Hideki

Search repository
MORITA, Satoru

× MORITA, Satoru

en MORITA, Satoru

Search repository
TAKAHASHI, Shinya

× TAKAHASHI, Shinya

en TAKAHASHI, Shinya

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2021 Hiroshima University Medical Press
主題
主題Scheme Other
主題 TEVAR (thoracic endovascular aortic repair)
主題
主題Scheme Other
主題 Aortic aneurysm
主題
主題Scheme Other
主題 Najuta stent graft
内容記述
内容記述 The purpose of this study was to review short-term results of aortic arch aneurysm treatment that were performed with fenestrated stent grafts (Najuta stent grafts) in our hospital. Nine patients of aortic arch aneurysm were treated with Najuta stent grafts between January 2015 and March 2018. Eight patients had a saccular aneurysm and one a dissecting aneurysm. A Najuta stent graft was deployed in the aortic arch in each patient. If necessary, a non-fenestrated stent graft was added, and bilateral axillary artery bypass or left subclavian artery embolisation was performed. Computed tomography (CT) examination was performed postoperatively, at 6 months, and yearly. In all patients, the stent grafts were deployed as planned. The blood flow of the brachiocephalic artery and left common carotid artery was maintained through fenestrations of the stent graft. Eight patients required occlusion of the left subclavian artery to get a sufficient proximal sealing zone; five of them were reconstructed. All patients were treated with fewer branch reconstructions than would have been required with conventional stent grafts. In one patient, a lower limb embolism occurred during the operation. On postoperative CT, endoleaks were observed in three patients. Coil embolisation of the left subclavian artery was performed within a year for two patients. The clinical course was evaluated for up to 4 years. Aneurysms shrank slightly in five patients, remained unchanged in three patients, and expanded in one patient. Najuta stent grafts performed well and enabled treatment of aortic arch aneurysms with minimal aortic branch reconstruction.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ DOI
関連識別子 10.24811/hjms.70.2-4_27
関連情報
識別子タイプ DOI
関連識別子 https://doi.org/10.24811/hjms.70.2-4_27
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 2433-7668
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 27
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 70, 号 2-4, p. 27-33, 発行日 2021-12
旧ID 51911
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:44:17.990412
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3