Improved Detectability of Hyper-Dense Nodules Using Dual-Energy Computed Tomography Scanning: Phantom Study Using Simulated Liver Harboring Nodules

https://hiroshima.repo.nii.ac.jp/records/2013749
https://hiroshima.repo.nii.ac.jp/records/2013749
f3ff42e4-2433-4e9e-ba15-64434db359c6
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_67_63.pdf HiroshimaJMedSci_67_63.pdf (680.5 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Improved Detectability of Hyper-Dense Nodules Using Dual-Energy Computed Tomography Scanning: Phantom Study Using Simulated Liver Harboring Nodules
言語 en
作成者 Bayasgalan, Enkhjargal

× Bayasgalan, Enkhjargal

en Bayasgalan, Enkhjargal

Search repository
Higaki, Toru

× Higaki, Toru

en Higaki, Toru

Search repository
Fukumoto, Wataru

× Fukumoto, Wataru

en Fukumoto, Wataru

Search repository
Nakamura, Yuko

× Nakamura, Yuko

en Nakamura, Yuko

Search repository
Chosa, Keigo

× Chosa, Keigo

en Chosa, Keigo

Search repository
Tatsugami, Fuminari

× Tatsugami, Fuminari

en Tatsugami, Fuminari

Search repository
Awai, Kazuo

× Awai, Kazuo

en Awai, Kazuo

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2018 Hiroshima University Medical Press
主題
主題Scheme Other
主題 liver tumor
主題
主題Scheme Other
主題 hyper-dense nodule
主題
主題Scheme Other
主題 dual-energy CT
主題
主題Scheme Other
主題 Phantom
主題
主題Scheme NDC
主題 490
内容記述
内容記述 The purpose of this study was to evaluate the detectability of hyper-dense nodules using dual-energy computed tomography (DECT) in a phantom. Arterial-phase hepatic dynamic computed tomography (CT) was conducted on small, medium, and large liver-simulating phantoms harboring simulated hypervascular tumors. We acquired 150 single-energy CT (SECT) and 150 DECT scans and measured the contrast-to-noise ratio (CNR) of the nodules. Alternative free response receiver observer characteristic (AFROC) curves of five radiologists’ readings of the SECT and DECT scans were compared to assess detectability of the hyper-dense nodules. For all phantoms, the CNR of nodules measured using DECT was significantly higher than that by using SECT (p < 0.001, all). In the AFROC study, DECT showed a significantly larger area under the curve than that with SECT (0.778 vs 0.499, p = 0.012). Detectability of high-density nodules was better with DECT scans than with SECT scans.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ DOI
関連識別子 10.24811/hjms.67.3_63
関連情報
識別子タイプ DOI
関連識別子 https://doi.org/10.24811/hjms.67.3_63
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 2433-7668
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 63
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 67, 号 3, p. 63-69, 発行日 2018-09
旧ID 46495
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:42:28.978090
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3