ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 51巻1号

Evaluation of Sustained Grip Strength for a Stroke Patient with a Mild Paresis

https://hiroshima.repo.nii.ac.jp/records/2013517
https://hiroshima.repo.nii.ac.jp/records/2013517
c117fc07-710b-426c-85b3-94382b8b2fe3
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_51_23.pdf HiroshimaJMedSci_51_23.pdf (763.0 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Evaluation of Sustained Grip Strength for a Stroke Patient with a Mild Paresis
言語 en
作成者 Kamimura, Tomoko

× Kamimura, Tomoko

en Kamimura, Tomoko

Search repository
Ikuta, Yoshikazu

× Ikuta, Yoshikazu

en Ikuta, Yoshikazu

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Stroke
主題
主題Scheme Other
主題 Hand
主題
主題Scheme Other
主題 Strength
主題
主題Scheme Other
主題 Activities of daily living
主題
主題Scheme NDC
主題 490
内容記述
内容記述 The purpose of this study was to investigate whether a sustained grip strength test is workable as an accurate assessment of activity limitation related to muscle weakness of the paretic hands of stroke patients with mild pareses. Sixty-one stroke patients with mild pareses participated in this study. The maximal grip strength and an ability to sustain grip strength were examined with the Sustained Grip Strength Test. The latter ability was measured by the sustained period of the maximal grip strength (a period that exhibited more than 80% of the peak force during a six-seconds trial). The activity limitation of squeezing an object was evaluated in four ADL tasks, and the difficulties were rated according to three scores. We found that there was a significant positive relationship between the degree of the task difficulty and the maximal grip strength for paretic hands whose sustained period was over three sec, in all four assessments (p < 0.05). However, for paretic hands whose sustained period was under three sec, no such relationship was found. Consequently, measuring both the maximal grip strength and the sustained period was needed to assess accurately an activity limitation related to muscle weakness of the paretic hands of stroke patients with mild pareses.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 23
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 51, 号 1, p. 23-31, 発行日 2002-03
旧ID 37674
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:35:37.861997
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3