| Item type |
デフォルトアイテムタイプ_(フル)(1) |
| 公開日 |
2023-03-18 |
| タイトル |
|
|
タイトル |
Comparison of Properties of Slow Pathway Potential between Successful and Unsuccessful Radiofrequency Applications in Patients who Underwent Catheter Ablation for Atrioventricular Nodal Reentrant Tachycardia |
|
言語 |
en |
| 作成者 |
Hirao, Hidekazu
Muraoka, Yuji
Yamagata, Togo
Matsuura, Hideo
Kajiyama, Goro
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Atrioventricular nodal reentrant tachycardia |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Radiofrequency catheter ablation |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Slow pathway potential |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Upper margin of coronary sinus ostium |
| 主題 |
|
|
主題Scheme |
NDC |
|
主題 |
490 |
| 内容記述 |
|
|
内容記述 |
Findings concerning selective slow pathway radiofrequency ablation for atrioventricular nodal reentrant tachycardia (A VNRT) using the slow pathway potential (SPP) guided method are reported. The electrogram at the SPP recording site showed double potentials consisting of the atrial potential (A) and SPP. However, SPP is usually recorded widely in the right atrial posteroseptal region. To examine whether there was any characteristic marker in the electrogram at the SPP recording site specific to successful RF application, the properties of SPP and its anatomical locations in both successful (S) (38 sites) and unsuccessful (UN) (28 sites) application sites were analyzed in 38 patients who underwent SPP-guided ablation. The distance between the upper margin of the coronary sinus ostium (UCSO) and the ablation catheter (ABL) (DUCSO-ABL) was shorter in S than in UN (2.3 ± 6.3 mm vs. 9.0 ± 5.2 mm below the level of UCSO, p < 0.001). The interval between A and SPP (A-SPP) was longer in S than in UN (44.2 ± 9.9 msec vs. 24.0 ± 7.0 msec, p < 0.001). RF applications at the more anterior sites with longer A-SPP were more successful than at other sites. The sensitivity and specificity of A-SPP (more than 40 msec) were superior to those of DUCSO-ABL (within 5 mm) as the marker for the successful application (sensitivity; 73.7% v.s. 68.4%, specificity; 100% v.s. 82.1 %, respectively). In conclusion, the sites with longer A-SPP might be specific for successful ablation. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Hiroshima University Medical Press |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
| 出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0018-2052 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00664312 |
| 開始ページ |
|
|
開始ページ |
15 |
| 書誌情報 |
Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences
巻 49,
号 1,
p. 15-27,
発行日 2000-03
|
| 旧ID |
37697 |