WEKO3
アイテム
Indoor Air Quality and Ventilation Strategies in the Use of Combustion Space Heating Appliances in Housing
https://hiroshima.repo.nii.ac.jp/records/2013356
https://hiroshima.repo.nii.ac.jp/records/201335601d25f38-ade9-4b8c-a354-1ffb392c4b50
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
| Item type | デフォルトアイテムタイプ_(フル)(1) | |||||||
|---|---|---|---|---|---|---|---|---|
| 公開日 | 2023-03-18 | |||||||
| タイトル | ||||||||
| タイトル | Indoor Air Quality and Ventilation Strategies in the Use of Combustion Space Heating Appliances in Housing | |||||||
| 言語 | en | |||||||
| 作成者 |
Setiani, Onny
× Setiani, Onny
|
|||||||
| アクセス権 | ||||||||
| アクセス権 | open access | |||||||
| アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||
| 主題 | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | Indoor air quality (IAQ) | |||||||
| 主題 | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | Combustion materials | |||||||
| 主題 | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | Natural ventilation | |||||||
| 主題 | ||||||||
| 主題Scheme | Other | |||||||
| 主題 | Humidification | |||||||
| 主題 | ||||||||
| 主題Scheme | NDC | |||||||
| 主題 | 490 | |||||||
| 内容記述 | ||||||||
| 内容記述 | Indoor air quality (IAQ) in the use of combustion appliances is important for adequate evaluation of air pollution health risks. Since people spend most of their time inside buildings, especially the elderly and children, their exposure to indoor air contaminants can increase health problems in the community. Combustion materials emitted from combustion space heating appliances in housing during the winter may become a serious problem to health, since sources of ventilation are usually left closed to obtain a comfortable temperature level. To evaluate the IAQ and factors that may decrease combustion materials emitted from heaters, a study was done by using a house exposure model. The study found that IAQ in an unventilated house during combustion heater use was poor due to lack of fresh air. When using a heater, natural ventilation should be used to dilute air contaminants emitted from the heater. A concentration of carbon dioxide at about 1000 ppm and a comfortable temperature of 20°C could be maintained by applying natural ventilation of about 0.12 m^2 during the use of an unvented kerosene space heater. However, ventilation also depends on the number of the occupants and the wind velocity. The use of a steamer is also important to provide optimum humidity levels without elevating the respirable dust concentration above the acceptable limit. | |||||||
| 言語 | en | |||||||
| 出版者 | ||||||||
| 出版者 | Hiroshima University Medical Press | |||||||
| 言語 | ||||||||
| 言語 | eng | |||||||
| 資源タイプ | ||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
| 資源タイプ | departmental bulletin paper | |||||||
| 出版タイプ | ||||||||
| 出版タイプ | VoR | |||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||
| 収録物識別子 | ||||||||
| 収録物識別子タイプ | ISSN | |||||||
| 収録物識別子 | 0018-2052 | |||||||
| 収録物識別子 | ||||||||
| 収録物識別子タイプ | NCID | |||||||
| 収録物識別子 | AA00664312 | |||||||
| 開始ページ | ||||||||
| 開始ページ | 163 | |||||||
| 書誌情報 |
Hiroshima Journal of Medical Sciences Hiroshima Journal of Medical Sciences 巻 43, 号 4, p. 163-167, 発行日 1994-12 |
|||||||
| 旧ID | 37895 | |||||||