Retrograde Cerebral and Coronary Perfusion for Acute Dissection of Stanford Type A with Destruction of the Right Coronary Ostia

https://hiroshima.repo.nii.ac.jp/records/2013327
https://hiroshima.repo.nii.ac.jp/records/2013327
50b9aebd-6383-4478-afda-a45b719db33a
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_42_117.pdf HiroshimaJMedSci_42_117.pdf (417.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Retrograde Cerebral and Coronary Perfusion for Acute Dissection of Stanford Type A with Destruction of the Right Coronary Ostia
言語 en
作成者 Sueda, Taijiro

× Sueda, Taijiro

en Sueda, Taijiro

Search repository
Hayashi, Saiho

× Hayashi, Saiho

en Hayashi, Saiho

Search repository
Nomimura, Takayuki

× Nomimura, Takayuki

en Nomimura, Takayuki

Search repository
Kurisu, Yoshihiro

× Kurisu, Yoshihiro

en Kurisu, Yoshihiro

Search repository
Orihashi, Kazumasa

× Orihashi, Kazumasa

en Orihashi, Kazumasa

Search repository
Shikata, Hiroo

× Shikata, Hiroo

en Shikata, Hiroo

Search repository
Matsuura, Yuichiro

× Matsuura, Yuichiro

en Matsuura, Yuichiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Retrograde cerebral perfusion
主題
主題Scheme Other
主題 Retrograde coronary sinus pefusion
主題
主題Scheme Other
主題 Acute aortic dissection
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Repair of acute aortic dissection with destruction of the right coronary ostia and aortic valve regurgitation is described. The patient was a 54 year-old female with Marfan syndrome, who was admitted to our hospital for acute dissection with annulo aortic ectasia, accompanied by myocardial ischemia of the inferior wall. Retrograde dissection to the aortic annulus and destruction of the right coronary ostia due to extended dissection were noted. Retrograde coronary infusion through the coronary sinus was conducted during replacement of aortic annulus by the Cabrol method in conjunction with supplementary vein grafting to the right coronary artery. Distal repair was carried out, supported by hypothermic circulatory arrest and retrograde cerebral perfusion through the superior vena caval cannula. Retrograde cerebral and coronary sinus perfusion have been shown to be quite effective for treating patients requiring complex reconstruction of the ascending aorta.
言語 en
出版者
出版者 Hiroshima University Medical Press
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 117
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 42, 号 3, p. 117-119, 発行日 1993-09
旧ID 37924
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:30:09.208454
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3