Functional Imaging of Hepatic Masses Using Computed Tomography |
|
言語 |
en |
作成者 |
FUJIKAWA, Koichi
YAMANE, Kosuke
NAKANISHI, Tadashi
KATSUTA, Shizutomo
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Functional imaging |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Hepatic tumor |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
Computed tomography |
主題 |
|
|
主題Scheme |
Other |
|
主題 |
CT data processing |
主題 |
|
|
主題Scheme |
NDC |
|
主題 |
490 |
内容記述 |
|
|
内容記述 |
In order to assess the usefulness of CT functional images, twenty one cases with liver masses were studied. We tried to minimize the motion artifacts by immobilizing the patients with a girdle in performing dynamic CT scans, and by discarding some of the segmented images with serious artifacts before constructing functional images. The qualities of images obtained were considered satisfactory. Of the several transit parameters obtained from the dynamic CT scans, we found the first moment (Ml) to be most useful and the effectiveness of Ml-functional images were studied. In all cases with hepatocellular carcinomas (12 cases) and intrahepatic cholangiocarcinomas (2 cases), the Ml-functional images showed the viable portions of tumors as accumulations of dark pixels reflecting rapid transit times due to arterial blood supply. In three cases with hepatic cavernous hemangiomas, the lesions were represented as bright areas with a well-defined border. In two cases with hepatic abscesses, the Ml-functional images suggested the presence of hyperemia in the surrounding tissue as demonstrated by bright pixels around the lesions. CT functional imaging was proved to be useful for evaluating the circulatory dynamics of contrast material and the differential diagnosis of liver tumors when conventional or dynamic CT studies failed to provide enough information. This technique enabled overall analysis of time-density curves for the entire plane of an image semiautomatically and without the subjective maneuver of setting ROI's (regions of interest). |
|
言語 |
en |
出版者 |
|
|
出版者 |
Hiroshima University School of Medicine |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
関連情報 |
|
|
|
識別子タイプ |
PMID |
|
|
関連識別子 |
3583800 |
収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0018-2052 |
収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00664312 |
開始ページ |
|
|
開始ページ |
113 |
書誌情報 |
Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences
巻 36,
号 1,
p. 113-120,
発行日 1987-03
|
旧ID |
49969 |