ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 広島大学の刊行物
  2. Hiroshima Journal of Medical Sciences
  3. 36巻1号

Functional Imaging of Hepatic Masses Using Computed Tomography

https://hiroshima.repo.nii.ac.jp/records/2013138
https://hiroshima.repo.nii.ac.jp/records/2013138
03f52c8c-14d8-496d-a6d0-079cc0d7f8c0
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_36_113.pdf HiroshimaJMedSci_36_113.pdf (8.2 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Functional Imaging of Hepatic Masses Using Computed Tomography
言語 en
作成者 FUJIKAWA, Koichi

× FUJIKAWA, Koichi

en FUJIKAWA, Koichi

Search repository
YAMANE, Kosuke

× YAMANE, Kosuke

en YAMANE, Kosuke

Search repository
NAKANISHI, Tadashi

× NAKANISHI, Tadashi

en NAKANISHI, Tadashi

Search repository
KATSUTA, Shizutomo

× KATSUTA, Shizutomo

en KATSUTA, Shizutomo

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Functional imaging
主題
主題Scheme Other
主題 Hepatic tumor
主題
主題Scheme Other
主題 Computed tomography
主題
主題Scheme Other
主題 CT data processing
主題
主題Scheme NDC
主題 490
内容記述
内容記述 In order to assess the usefulness of CT functional images, twenty one cases with liver masses were studied. We tried to minimize the motion artifacts by immobilizing the patients with a girdle in performing dynamic CT scans, and by discarding some of the segmented images with serious artifacts before constructing functional images. The qualities of images obtained were considered satisfactory. Of the several transit parameters obtained from the dynamic CT scans, we found the first moment (Ml) to be most useful and the effectiveness of Ml-functional images were studied. In all cases with hepatocellular carcinomas (12 cases) and intrahepatic cholangiocarcinomas (2 cases), the Ml-functional images showed the viable portions of tumors as accumulations of dark pixels reflecting rapid transit times due to arterial blood supply. In three cases with hepatic cavernous hemangiomas, the lesions were represented as bright areas with a well-defined border. In two cases with hepatic abscesses, the Ml-functional images suggested the presence of hyperemia in the surrounding tissue as demonstrated by bright pixels around the lesions. CT functional imaging was proved to be useful for evaluating the circulatory dynamics of contrast material and the differential diagnosis of liver tumors when conventional or dynamic CT studies failed to provide enough information. This technique enabled overall analysis of time-density curves for the entire plane of an image semiautomatically and without the subjective maneuver of setting ROI's (regions of interest).
言語 en
出版者
出版者 Hiroshima University School of Medicine
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ PMID
関連識別子 3583800
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 113
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 36, 号 1, p. 113-120, 発行日 1987-03
旧ID 49969
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:24:38.370968
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3