Clinical Evaluation and Metabolism of Sevoflurane in Patients

https://hiroshima.repo.nii.ac.jp/records/2013135
https://hiroshima.repo.nii.ac.jp/records/2013135
8fff49ff-76f4-4fd3-b263-8970c9a319f6
名前 / ファイル ライセンス アクション
HiroshimaJMedSci_36_93.pdf HiroshimaJMedSci_36_93.pdf (591.7 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Clinical Evaluation and Metabolism of Sevoflurane in Patients
言語 en
作成者 KIKUCHI, Hirosato

× KIKUCHI, Hirosato

en KIKUCHI, Hirosato

Search repository
MORIO, Michio

× MORIO, Michio

en MORIO, Michio

Search repository
FUJII, Kohyu

× FUJII, Kohyu

en FUJII, Kohyu

Search repository
MUKAIDA, Keiko

× MUKAIDA, Keiko

en MUKAIDA, Keiko

Search repository
HORIBE, Mayumi

× HORIBE, Mayumi

en HORIBE, Mayumi

Search repository
DAVIDKOVA, Tatiana Ivanova

× DAVIDKOVA, Tatiana Ivanova

en DAVIDKOVA, Tatiana Ivanova

Search repository
KAWACHI, Shoji

× KAWACHI, Shoji

en KAWACHI, Shoji

Search repository
SATO, Nobuyoshi

× SATO, Nobuyoshi

en SATO, Nobuyoshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
主題Scheme Other
主題 Anesthetics
主題
主題Scheme Other
主題 volatile: Sevoflurane: Fluoride
主題
主題Scheme Other
主題 inorganic: Fluoride
主題
主題Scheme Other
主題 serum
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Sevoflurane was submitted to Phase II studies in patients following Phase I studies. Sevoflurane, 2% inspired during maintenance, was administered with 50% N2O in oxygen to produce surgical anesthesia in 9 orthopedic patients of ASA Physical Status I. Under controlled ventilation, endotracheal concentration of sevoflurane was recorded. The blood concentration of sevoflurane was measured during and after the inhalation. Serum, urinary inorganic fluoride, and glucuronide of hexafluoroisopropanol were analysed with ion chromatographic analyzer. The patient inhaled sevoflurane for 3.5 ± 1.6 hr. All the patients were anesthetized and operated uneventfully. Postoperative laboratory findings showed no unexplainable abnormality. The end expiratory concentration of sevoflurane reached a plateau in 4.0 ± 0.8 min and fell rapidly after discontinuation of sevoflurane. Blood concentration of sevoflurane was about 500 μM during inhalation. It decreased promptly after termination of sevoflurane and was not correlated with anesthetic time. The time for verbal response after discontinuation was 11.8 ± 4.2 min. The serum concentration of inorganic fluoride increased after inhalation and reached a plateau (13.7 ± 8.2 μM) in 120 min. The level lasted for 120 min after anesthesia and fell by half at 12 hr after anesthesia. Urinary fluoride concentration varied from 20 to 3,000 μM during the first 12 hr urine, and showed its maximum in the first postoperative 12 or 24 hr urine. The findings that sevoflurane with nitrous oxide and oxygen produced surgical anesthesia without any sequelae and that the serum fluoride level did not exceed the nephrotoxic level warrent the further clinical evaluation in a wider range of subjects.
言語 en
内容記述
内容記述タイプ Other
内容記述 A part of this work was supported by a Research Grant from the Japanese Ministry of Education, Science and Culture and presented at the 8th European Congress of Anaesthesiology, Vienna, Austria, in September, 1986.
出版者
出版者 Hiroshima University School of Medicine
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ PMID
関連識別子 3583809
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0018-2052
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00664312
開始ページ
開始ページ 93
書誌情報 Hiroshima Journal of Medical Sciences
Hiroshima Journal of Medical Sciences

巻 36, 号 1, p. 93-97, 発行日 1987-03
旧ID 49966
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-23 06:24:31.755077
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3