{"created":"2025-02-21T05:14:27.718490+00:00","id":2009935,"links":{},"metadata":{"_buckets":{"deposit":"54251d35-45f2-4148-9ded-db5824bd7d2a"},"_deposit":{"created_by":41,"id":"2009935","owners":[41],"pid":{"revision_id":0,"type":"depid","value":"2009935"},"status":"published"},"_oai":{"id":"oai:hiroshima.repo.nii.ac.jp:02009935","sets":["1730444907710"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"弱視児に適した線の条件に関する実験的研究 : 破線の条件の検討","subitem_title_language":"ja"},{"subitem_title":"Evaluation of the Legibility of Broken Lines for Partial Sight","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 秀之","creatorNameLang":"ja"},{"creatorName":"Kobayashi, Hideyuki","creatorNameLang":"en"}],"familyNames":[{"familyName":"小林","familyNameLang":"ja"},{"familyName":"Kobayashi","familyNameLang":"en"}],"givenNames":[{"givenName":"秀之","givenNameLang":"ja"},{"givenName":"Hideyuki","givenNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_subject":"partial sight","subitem_subject_scheme":"Other"},{"subitem_subject":"low vision","subitem_subject_scheme":"Other"},{"subitem_subject":"legibility of broken lines","subitem_subject_scheme":"Other"},{"subitem_subject":"弱視","subitem_subject_scheme":"Other"},{"subitem_subject":"破線","subitem_subject_scheme":"Other"},{"subitem_subject":"視知覚","subitem_subject_scheme":"Other"},{"subitem_subject":"140","subitem_subject_scheme":"NDC"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"The present study was designed to investigate the legibility of broken lines for persons with partial sight. The subjects were 10 persons with simulated partial sight, and 4 persons with partial sight. The simulation was obtained using filters and convex lenses. The 30 kind of broken lines was evaluated by the original test that the subjects were read directions of the broken lines in distinction from solid lines. The thickness of lines varied from 0.1mm. to 0.7mm. in 4 steps. The results were as follows: (1) For all subjects, the conditions of broken lines that the spaces width were 0.5mm and 1.0mm were inadequate for partial sight. (2) The broken lines with wide space were inadequate for partial sight. (3) For subjects with partial sight, adequate spaces width of broken lines were equally and over to Landolt's rings gap that were measured the near visual acuity.","subitem_description_language":"en"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"広島大学学校教育学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0387-4850","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AN00213326","subitem_source_identifier_type":"NCID"}]},"item_1617187024783":{"attribute_name":"Page Start","attribute_value_mlt":[{"subitem_start_page":"99"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"106","bibliographicPageStart":"99","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"広島大学学校教育学部紀要. 第一部"},{"bibliographic_title":"Bulletin of the Faculty of School Education, Hiroshima University. Part I"}]}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-03-18"}],"displaytype":"simple","filename":"BullFacSchEduc-HiroshimaUniv-Pt1_22_99.pdf","filesize":[{"value":"755.4 KB"}],"mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hiroshima.repo.nii.ac.jp/record/2009935/files/BullFacSchEduc-HiroshimaUniv-Pt1_22_99.pdf"},"version_id":"1036a6e8-2193-41f8-a5b7-12d34691df27"}]},"item_1732771732025":{"attribute_name":"旧ID","attribute_value":"27358"},"item_title":"弱視児に適した線の条件に関する実験的研究 : 破線の条件の検討","item_type_id":"40003","owner":"41","path":["1730444907710"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-03-18"},"publish_date":"2023-03-18","publish_status":"0","recid":"2009935","relation_version_is_last":true,"title":["弱視児に適した線の条件に関する実験的研究 : 破線の条件の検討"],"weko_creator_id":"41","weko_shared_id":-1},"updated":"2025-02-22T06:38:41.933047+00:00"}