A self-calibration scheme for two-dimensional free-form probing measurement under the assumption of rigid-body machine kinematic model

https://hiroshima.repo.nii.ac.jp/records/2007693
https://hiroshima.repo.nii.ac.jp/records/2007693
21e1c828-47b2-4cd8-a175-769855a3e9a0
名前 / ファイル ライセンス アクション
Measurement_222_113586.pdf Measurement_222_113586.pdf (3.3 MB)
 Download is available from 2025/9/20.
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2024-11-29
タイトル
タイトル A self-calibration scheme for two-dimensional free-form probing measurement under the assumption of rigid-body machine kinematic model
言語 en
作成者 Onishi, Shota

× Onishi, Shota

en Onishi, Shota

Search repository
Ibaraki, Soichi

× Ibaraki, Soichi

en Ibaraki, Soichi

Search repository
Yamaguchi, Masashi

× Yamaguchi, Masashi

en Yamaguchi, Masashi

Search repository
Sugimoto, Takao

× Sugimoto, Takao

en Sugimoto, Takao

Search repository
アクセス権
アクセス権 embargoed access
アクセス権URI http://purl.org/coar/access_right/c_f1cf
権利情報
言語 en
権利情報 © 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報
言語 en
権利情報 This is not the published version. Please cite only the published version.
権利情報
言語 ja
権利情報 この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。
主題
言語 en
主題Scheme Other
主題 Self-calibration
主題
言語 en
主題Scheme Other
主題 On-machine measurement
主題
言語 en
主題Scheme Other
主題 Geometric error
主題
言語 en
主題Scheme Other
主題 Five-axis machine tool
主題
言語 en
主題Scheme Other
主題 Metrology
内容記述
内容記述 A major uncertainty contributor to the on-machine probing is linear axis kinematic errors. This paper proposes a novel self-calibration scheme to separate the workpiece geometry and machine tool kinematic errors from the probed profiles. Many self-calibration schemes have been well developed, but they are limited to either of the straightness, roundness, and two-dimensional (2D) grid point positions, since they require the probed points being in a closed set, as the workpiece is rotated or translated. This paper proposes its extension to a free-form 2D geometry. A key idea is on the assumption that the machine tool’s positioning error is in accordance with the rigid-body kinematic model. It makes linear axis error motions, represented in a look-up table format, be in a closed set. Two experimental case studies are presented. The uncertainty assessment is essential to investigate the effectiveness of the proposed scheme for the given workpiece geometry.
言語 en
出版者
出版者 Elsevier
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.measurement.2023.113586
開始ページ
開始ページ 113586
書誌情報 en : Measurement

巻 222, p. 113586, 発行日 2023-09-20
旧ID 55821
備考 The full-text file will be made open to the public on 20 September 2025 in accordance with publisher's 'Terms and Conditions for Self-Archiving'
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 04:00:10.903256
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3