ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文等

Compatibility of tissue conditioners and dental stones: Effect on surface roughness

https://hiroshima.repo.nii.ac.jp/records/2007526
https://hiroshima.repo.nii.ac.jp/records/2007526
a8467ace-101d-4447-8ff1-8a0b42da3d8a
名前 / ファイル ライセンス アクション
JProsthDent_93_274.pdf JProsthDent_93_274.pdf (1.6 MB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Compatibility of tissue conditioners and dental stones: Effect on surface roughness
言語 en
作成者 Murata, Hiroshi

× Murata, Hiroshi

en Murata, Hiroshi

Search repository
Hong, Guang

× Hong, Guang

en Hong, Guang

Search repository
Li, Ying Ai

× Li, Ying Ai

en Li, Ying Ai

Search repository
Hamada, Taizo

× Hamada, Taizo

en Hamada, Taizo

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2005 The Editorial Council of The Journal of Prosthetic Dentistry.
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Statement of problem. Although the primary use of tissue conditioners is to treat abused mucosa, these materials are also frequently used as functional impression materials. No information was identified on the effect that these materials may have on the surface of the resultant dental stone cast. Purpose. This study evaluated the compatibility of 3 tissue conditioners with dental stones and changes in surface conditions over time. Material and methods. Three tissue conditioners (COE-comfort, Soft-conditioner, and Visco-gel) and 4 dental stones (Capstone DF, New Plastone, Die Stone, and New Fujirock) were evaluated. One impression material (Examixfine) was used as a control. Tissue conditioner disks were made by pouring freshly mixed material into a polypropylene container, pressing the material down with a glass plate, and then removing the plate 2 hours later. The disks were then stored in distilled water for 0 or 24 hours, or 3, 7, or 14 days. Subsequently, each dental stone was mixed and poured over the top of each disk and allowed to remain for 60 minutes. Twenty-five disk-shaped specimens, 18 × 2 mm, for each tissue conditioner/stone cast combination were prepared. Mean surface roughness (Ra) values of the dental stone casts made from the tissue conditioners were determined using a profilometer. Five measurements for each specimen were made. Data were analyzed with 1- and 3-way analysis of variance and the Student-Newman-Keuls test (α=.05). Detail reproduction was also determined using a ruled test block, as specified in ISO specification 4823. Results.Contribution ratios determined by 3-way analysis of variance indicated that the surface roughness values were significantly more influenced by the time of immersion in water (P<.0005, contribution ratio ρ=37%), than the type of tissue conditioner (P<.0005, ρ=19%) or dental stone used (P<.0005, ρ=1%). The best surface quality was obtained with a New Fujirock cast (0.81 ± 0.06 μm), followed by New Plastone (0.83 ± 0.12 μm) and Die Stone (0.85 ± 0.05 μm) casts, in combination with Visco-gel without immersion in water, and those were nearly equivalent in surface roughness to a Die stone cast from Examixfine. The surface roughness values of all specimens, especially the COE-comfort/stone cast combinations, significantly increased with tissue conditioner immersion time (P<.0005). Visco-gel tended to produce a better surface quality during the test periods than the other materials. All stone casts made from the tissue conditioners not immersed in water reproduced 20-μm or 50-μm lines, while the detail diminished over time with immersion. Conclusion. The type of tissue conditioner, and especially immersion time, had a significant effect on the surface quality of dental stone casts. The type of dental stone used is less important.
言語 en
出版者
出版者 The Editorial Council of The Journal of Prosthetic Dentistry.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1016/j.prosdent.2004.12.011
関連情報
識別子タイプ PMID
関連識別子 15775929
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1016/j.prosdent.2004.12.011
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00705599
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0022-3913
開始ページ
開始ページ 274
書誌情報 Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry

巻 93, 号 3, p. 274-281, 発行日 2005-05
旧ID 19887
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:54:45.582046
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3