{"created":"2025-02-21T03:46:10.325754+00:00","id":2007247,"links":{},"metadata":{"_buckets":{"deposit":"bd9918e2-8758-437c-a94d-41ac60c67d29"},"_deposit":{"created_by":41,"id":"2007247","owners":[41],"pid":{"revision_id":0,"type":"depid","value":"2007247"},"status":"published"},"_oai":{"id":"oai:hiroshima.repo.nii.ac.jp:02007247","sets":["1730444907710"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakakura, Shunsuke","creatorNameLang":"en"}],"familyNames":[{"familyName":"Nakakura","familyNameLang":"en"}],"givenNames":[{"givenName":"Shunsuke","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Mori, Etsuko","creatorNameLang":"en"}],"familyNames":[{"familyName":"Mori","familyNameLang":"en"}],"givenNames":[{"givenName":"Etsuko","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nagatomi, Nozomi","creatorNameLang":"en"}],"familyNames":[{"familyName":"Nagatomi","familyNameLang":"en"}],"givenNames":[{"givenName":"Nozomi","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tabuchi, Hitoshi","creatorNameLang":"en"}],"familyNames":[{"familyName":"Tabuchi","familyNameLang":"en"}],"givenNames":[{"givenName":"Hitoshi","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kiuchi, Yoshiaki","creatorNameLang":"en"}],"familyNames":[{"familyName":"Kiuchi","familyNameLang":"en"}],"givenNames":[{"givenName":"Yoshiaki","givenNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2012 ASCRS and ESCRS"},{"subitem_rights":"This is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_subject":"490","subitem_subject_scheme":"NDC"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"PURPOSE: To evaluate the congruity of anterior chamber depth (ACD) measurements using 4 devices. SETTING: Saneikai Tsukazaki Hospital, Himeji City, Japan. DESIGN: Comparative case series. METHODS: In 1 eye of 42 healthy participants, the ACD was measured by 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT), partial coherence interferometry (PCI), Scheimpflug imaging, and ultrasound biomicroscopy (UBM). The differences between the measurements were evaluated by 2-way analysis of variance and post hoc analysis. Agreement between the measurements was evaluated using Bland-Altman analysis. To evaluate the true ACD using PCI, the automatically calculated ACD minus the central corneal thickness measured by CAS-OCT was defined as PCI true. Two ACD measurements were also taken with CAS-OCT. RESULTS: The mean ACD was 3.72 mm G 0.23 (SD) (PCI), 3.18 G 0.23 mm (PCI true), 3.24 G 0.25 mm (Scheimpflug), 3.03G 0.25 mm (UBM), 3.14 G 0.24 mm (CAS-OCT auto), and 3.12 G 0.24 mm (CAS-OCT manual). A significant difference was observed between PCI biometry, Scheimpflug imaging, and UBM measurements and the other methods. Post hoc analysis showed no significant differences between PCI true and CAS-OCT auto or between the CAS-OCT auto and CAS-OCT manual. Strong correlations were observed between all measurements; however, Bland-Altman analysis showed good agreement only between PCI true and Scheimpflug imaging and between CAS-OCT auto and CAS OCT manual. CONCLUSION: The ACD measurements obtained from PCI biometry, Scheimpflug imaging, CAS-OCT, and UBM were significantly different and not interchangeable except for PCI true and CAS-OCT auto and CAS-OCT auto and CAS-OCT manual. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.","subitem_description_language":"en"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"Elsevier Inc."}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0886-3350","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA10688328","subitem_source_identifier_type":"NCID"}]},"item_1617187024783":{"attribute_name":"Page Start","attribute_value_mlt":[{"subitem_start_page":"1207"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"1213","bibliographicPageStart":"1207","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"Journal of Cataract & Refractive Surgery"},{"bibliographic_title":"Journal of Cataract & Refractive Surgery"}]}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_b1a7d7d4d402bcce","subitem_version_type":"AO"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.jcrs.2012.02.036","subitem_relation_type_select":"DOI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"22613688","subitem_relation_type_select":"PMID"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-03-18"}],"displaytype":"simple","filename":"JCRS_38_1207.pdf","filesize":[{"value":"783.4 KB"}],"mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hiroshima.repo.nii.ac.jp/record/2007247/files/JCRS_38_1207.pdf"},"version_id":"990edbcd-54f9-4d48-a634-11d76d1956af"}]},"item_1732771732025":{"attribute_name":"旧ID","attribute_value":"45956"},"item_title":"Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy","item_type_id":"40003","owner":"41","path":["1730444907710"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-03-18"},"publish_date":"2023-03-18","publish_status":"0","recid":"2007247","relation_version_is_last":true,"title":["Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy"],"weko_creator_id":"41","weko_shared_id":-1},"updated":"2025-02-21T09:33:43.347818+00:00"}