{"created":"2025-02-21T03:41:39.566012+00:00","id":2007111,"links":{},"metadata":{"_buckets":{"deposit":"6bf81162-eb74-4e00-8fa7-da9f8d86d3f6"},"_deposit":{"created_by":41,"id":"2007111","owners":[41],"pid":{"revision_id":0,"type":"depid","value":"2007111"},"status":"published"},"_oai":{"id":"oai:hiroshima.repo.nii.ac.jp:02007111","sets":["1730444907710"]},"author_link":[],"control_number":"2007111","item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"Machine tool calibration: Measurement, modeling, and compensation of machine tool errors","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Gao, Wei","creatorNameLang":"en"}],"familyNames":[{"familyName":"Gao","familyNameLang":"en"}],"givenNames":[{"givenName":"Wei","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Ibaraki, Soichi","creatorNameLang":"en"}],"familyNames":[{"familyName":"Ibaraki","familyNameLang":"en"}],"givenNames":[{"givenName":"Soichi","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Donmez, M. Alkan","creatorNameLang":"en"}],"familyNames":[{"familyName":"Donmez","familyNameLang":"en"}],"givenNames":[{"givenName":"M. Alkan","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kono, Daisuke","creatorNameLang":"en"}],"familyNames":[{"familyName":"Kono","familyNameLang":"en"}],"givenNames":[{"givenName":"Daisuke","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Mayer, J.R.R.","creatorNameLang":"en"}],"familyNames":[{"familyName":"Mayer","familyNameLang":"en"}],"givenNames":[{"givenName":"J.R.R.","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Chen, Yuan-Liu","creatorNameLang":"en"}],"familyNames":[{"familyName":"Chen","familyNameLang":"en"}],"givenNames":[{"givenName":"Yuan-Liu","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Szipka, Károly","creatorNameLang":"en"}],"familyNames":[{"familyName":"Szipka","familyNameLang":"en"}],"givenNames":[{"givenName":"Károly","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Archenti, Andreas","creatorNameLang":"en"}],"familyNames":[{"familyName":"Archenti","familyNameLang":"en"}],"givenNames":[{"givenName":"Andreas","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Linares, Jean-Marc","creatorNameLang":"en"}],"familyNames":[{"familyName":"Linares","familyNameLang":"en"}],"givenNames":[{"givenName":"Jean-Marc","givenNameLang":"en"}]},{"creatorNames":[{"creatorName":"Suzuki, Norikazu","creatorNameLang":"en"}],"familyNames":[{"familyName":"Suzuki","familyNameLang":"en"}],"givenNames":[{"givenName":"Norikazu","givenNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_rights":"© 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/","subitem_rights_language":"en"},{"subitem_rights":"この論文は出版社版ではありません。引用の際には出版社版をご確認、ご利用ください。","subitem_rights_language":"ja"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_subject":"Machine tool","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Uncertainty","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Self-calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Machine learning","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Advanced technologies for the calibration of machine tools are presented. Kinematic errors independently of their causes are classified into errors within one-axis as intra-axis errors, errors between axes as inter-axis errors, and as volumetric errors. As the major technological elements of machine tool calibration, the measurement methods, modeling theories, and compensation strategies of the machine tool errors are addressed. The criteria for selecting a combination of the technological elements for machine tool calibration from the point of view of accuracy, complexity, and cost are provided. Recent applications of artificial intelligence and machine learning in machine tool calibration are introduced. Remarks are also made on future trends in machine tool calibration.","subitem_description_language":"en"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"Elsevier","subitem_publisher_language":"en"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0890-6955","subitem_source_identifier_type":"EISSN"},{"subitem_source_identifier":"AA11531434","subitem_source_identifier_type":"NCID"}]},"item_1617187024783":{"attribute_name":"Page Start","attribute_value_mlt":[{"subitem_start_page":"104017"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-03-29","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"104017","bibliographicVolumeNumber":"187","bibliographic_titles":[{"bibliographic_title":"International Journal of Machine Tools and Manufacture","bibliographic_titleLang":"en"}]}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1016/j.ijmachtools.2023.104017","subitem_relation_type_select":"DOI"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-06-28"}],"displaytype":"simple","fileDate":[{"fileDateType":"Available","fileDateValue":"2025-03-29"}],"filename":"IJMTM_187_104017.pdf","filesize":[{"value":"29.6 MB"}],"mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hiroshima.repo.nii.ac.jp/record/2007111/files/IJMTM_187_104017.pdf"},"version_id":"ae7168c6-821e-487e-b467-8e191ebf5c72"}]},"item_1732771732025":{"attribute_name":"旧ID","attribute_value":"54007"},"item_title":"Machine tool calibration: Measurement, modeling, and compensation of machine tool errors","item_type_id":"40003","owner":"41","path":["1730444907710"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-06-28"},"publish_date":"2023-06-28","publish_status":"0","recid":"2007111","relation_version_is_last":true,"title":["Machine tool calibration: Measurement, modeling, and compensation of machine tool errors"],"weko_creator_id":"41","weko_shared_id":-1},"updated":"2025-03-31T04:48:00.620265+00:00"}