| Item type |
デフォルトアイテムタイプ_(フル)(1) |
| 公開日 |
2023-03-18 |
| タイトル |
|
|
タイトル |
Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume? |
|
言語 |
en |
| 作成者 |
Horiguchi, Jun
Shen, Yun
Akiyama, Yuuji
Hirai, Nobuhiko
Sasaki, Kosuke
Ishifuro, Minoru
Ito, Katsuhide
|
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 権利情報 |
|
|
権利情報 |
Copyright (c) 2006 Springer-Verlag. "The original publication is available at www.springerlink.com" |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Calcification |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Coronary artery |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Electron beam CT |
| 主題 |
|
|
主題Scheme |
Other |
|
主題 |
Spiral CT |
| 主題 |
|
|
主題Scheme |
NDC |
|
主題 |
490 |
| 内容記述 |
|
|
内容記述 |
Objective: The purpose of this study is to investigate how accurately we can measure CAC volume using electron beam computed tomography (CT) and 16-slice spiral CT. Materials and Methods: CAC models with known volume attached to a cardiac phantom were scanned. The error of measurement, variability between measured and real volumes and inter-scan measurement variability were obtained. For spiral CT, 7 different parameters; i.e. (1) slice-thickness (0.625mm, 1.25mm and 2.5mm), (2) retrospective spiral electrocardiograph (ECG)-gated or prospective axial ECG-triggering, (3) overlapping or non-overlapping, were included. Results: The error of measurement was 150n electron beam CT and 8-2027777735740n spiral CT. CAC volumes were underestimated in 92-0x1.4b3a0b6a4aap-149nd overestimated in 81024570420f the electron beam CT scans. Volumes were underestimated in 79%, correct in 5-0x1.86278bfffa1a8p-150nd overestimated in 1626651131640f the spiral CT scans. The best measurement and the least variability was observed on 0.625mm retrospective spiral ECG-gated CT (error of 8%), a significant result (t-test: p<0.01) when compared with electron beam CT. Conclusion: CAC volume measurement on CT scanners may be significantly different and often underestimates the real volume of CAC. For precise evaluation of CAC volume, thin-slice retrospective spiral ECG-gated scan using a spiral CT scanner is desirable. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
Springer |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| 出版タイプ |
|
|
出版タイプ |
AO |
|
出版タイプResource |
http://purl.org/coar/version/c_b1a7d7d4d402bcce |
| 関連情報 |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.1007/s00330-005-2904-9 |
| 関連情報 |
|
|
|
識別子タイプ |
PMID |
|
|
関連識別子 |
16175352 |
| 関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
http://dx.doi.org/10.1007/s00330-005-2904-9 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0938-7994 |
| 収録物識別子 |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA10824302 |
| 開始ページ |
|
|
開始ページ |
374 |
| 書誌情報 |
European Radiology
European Radiology
巻 16,
号 2,
p. 374-380,
発行日 2006-02
|
| 旧ID |
17068 |