Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?

https://hiroshima.repo.nii.ac.jp/records/2006860
https://hiroshima.repo.nii.ac.jp/records/2006860
b3c85fcb-6185-4ba3-aa8c-bc9fd8152639
名前 / ファイル ライセンス アクション
EuroRadiol_16_374.pdf EuroRadiol_16_374.pdf (759.8 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?
言語 en
作成者 Horiguchi, Jun

× Horiguchi, Jun

en Horiguchi, Jun

Search repository
Shen, Yun

× Shen, Yun

en Shen, Yun

Search repository
Akiyama, Yuuji

× Akiyama, Yuuji

en Akiyama, Yuuji

Search repository
Hirai, Nobuhiko

× Hirai, Nobuhiko

en Hirai, Nobuhiko

Search repository
Sasaki, Kosuke

× Sasaki, Kosuke

en Sasaki, Kosuke

Search repository
Ishifuro, Minoru

× Ishifuro, Minoru

en Ishifuro, Minoru

Search repository
Ito, Katsuhide

× Ito, Katsuhide

en Ito, Katsuhide

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 Copyright (c) 2006 Springer-Verlag. "The original publication is available at www.springerlink.com"
主題
主題Scheme Other
主題 Calcification
主題
主題Scheme Other
主題 Coronary artery
主題
主題Scheme Other
主題 Electron beam CT
主題
主題Scheme Other
主題 Spiral CT
主題
主題Scheme NDC
主題 490
内容記述
内容記述 Objective: The purpose of this study is to investigate how accurately we can measure CAC volume using electron beam computed tomography (CT) and 16-slice spiral CT. Materials and Methods: CAC models with known volume attached to a cardiac phantom were scanned. The error of measurement, variability between measured and real volumes and inter-scan measurement variability were obtained. For spiral CT, 7 different parameters; i.e. (1) slice-thickness (0.625mm, 1.25mm and 2.5mm), (2) retrospective spiral electrocardiograph (ECG)-gated or prospective axial ECG-triggering, (3) overlapping or non-overlapping, were included. Results: The error of measurement was 150n electron beam CT and 8-2027777735740n spiral CT. CAC volumes were underestimated in 92-0x1.4b3a0b6a4aap-149nd overestimated in 81024570420f the electron beam CT scans. Volumes were underestimated in 79%, correct in 5-0x1.86278bfffa1a8p-150nd overestimated in 1626651131640f the spiral CT scans. The best measurement and the least variability was observed on 0.625mm retrospective spiral ECG-gated CT (error of 8%), a significant result (t-test: p<0.01) when compared with electron beam CT. Conclusion: CAC volume measurement on CT scanners may be significantly different and often underestimates the real volume of CAC. For precise evaluation of CAC volume, thin-slice retrospective spiral ECG-gated scan using a spiral CT scanner is desirable.
言語 en
出版者
出版者 Springer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AO
出版タイプResource http://purl.org/coar/version/c_b1a7d7d4d402bcce
関連情報
識別子タイプ DOI
関連識別子 10.1007/s00330-005-2904-9
関連情報
識別子タイプ PMID
関連識別子 16175352
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1007/s00330-005-2904-9
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0938-7994
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA10824302
開始ページ
開始ページ 374
書誌情報 European Radiology
European Radiology

巻 16, 号 2, p. 374-380, 発行日 2006-02
旧ID 17068
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:34:09.573054
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3