Rapid and Highly Sensitive Determination of Low-Molecular-Weight Carbonyl Compounds in Drinking Water and Natural Water by Preconcentration HPLC with 2,4-Dinitrophenylhydrazine

https://hiroshima.repo.nii.ac.jp/records/2006219
https://hiroshima.repo.nii.ac.jp/records/2006219
8d4aad0e-c343-40fa-a0d0-3af7a7ae9395
名前 / ファイル ライセンス アクション
AnalySci_22_1509.pdf AnalySci_22_1509.pdf (90.9 KB)
Item type デフォルトアイテムタイプ_(フル)(1)
公開日 2023-03-18
タイトル
タイトル Rapid and Highly Sensitive Determination of Low-Molecular-Weight Carbonyl Compounds in Drinking Water and Natural Water by Preconcentration HPLC with 2,4-Dinitrophenylhydrazine
言語 en
作成者 Takeda, Kazuhiko

× Takeda, Kazuhiko

en Takeda, Kazuhiko

Search repository
Katoh, Shinya

× Katoh, Shinya

en Katoh, Shinya

Search repository
Nakatani, Nobutake

× Nakatani, Nobutake

en Nakatani, Nobutake

Search repository
Sakugawa, Hiroshi

× Sakugawa, Hiroshi

en Sakugawa, Hiroshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
権利情報 2006 © The Japan Society for Analytical Chemistry
主題
主題Scheme NDC
主題 430
内容記述
内容記述 The aim of this research was to develop a simple procedure for a highly sensitive determination of low-molecular-weight (LMW) carbonyl compounds in drinking water and natural water. We employed a preconcentration HPLC system with 2,4-dinitrophenylhydrazine (DNPH) for the determination of LMW carbonyl compounds. A C-18 reverse-phase preconcentration column was used instead of a sample loop at the sample injection valve. A 0.1 - 5.0 mL portion of the derivatized sample solution was injected with a gas-tight syringe, and a 15% acetonitrile aqueous solution was pushed through the preconcentration column to remove the unreacted excess DNPH, which caused serious interference in the determination of formaldehyde. The detection limits were 1 - 3 nM with a relative standard deviation of 2 - 5% for 20 nM standard solutions (n = 5). The calibration curves were essentially unaffected by coexisting sea salts. Applications to commercial mineral water, tap water, river water, pond water and seawater are presented.
言語 en
内容記述
内容記述タイプ Other
内容記述 This work was partially supported by a Grant-in-Aid for Scientific Research No. 15510002 from the Ministry of Education, Culture, Sports, Science and Technology, Japan.
出版者
出版者 The Japan Society for Analytical Chemistry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
識別子タイプ DOI
関連識別子 10.2116/analsci.22.1509
関連情報
識別子タイプ DOI
関連識別子 https://doi.org/10.2116/analsci.22.1509
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0910-6340
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 1348-2246
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA10500785
開始ページ
開始ページ 1509
書誌情報 Analytical Sciences
Analytical Sciences

巻 22, 号 12, p. 1509-1514, 発行日 2006-12
旧ID 47033
戻る
0
views
See details
Views

Versions

Ver.1 2025-02-21 03:14:28.363920
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3